| Retention or Detention + Plants | Detention + Plants |
| Buffer Width (ft) | 100.00 |
| Buffer Length (ft) | 500.00 |
| Buffer Depth (ft) | 0.50 |
| Width of Area Feeding Buffer (ft) | 130.00 |
| Water storage capacity of soil (in/in) | 0.15 |
| Slope of Buffer (%) | 6.00 |
| Runoff Area (Width of Area Feeding Buffer x Length) (acres) | 1.492 |
| Buffer Area (Width x Length) (acres) | 1.148 |
| Contributing Area (Runoff Area + Buffer Area) (acres) | 2.640 |
| Watershed Area (acres) | 1.50 |
Warning: the Contributing Area (Runoff Area + Buffer Area) is 2.640 acres, but the catchment's area (Watershed Area, from 1. Enter Catchment) is 1.500 acres. They must be equal (within 1 %): the catchment is the area that drains to the buffer plus the buffer itself. The loads come from the catchment's area; the treatment is calculated from these dimensions. With this length and width, a Width of Area Feeding Buffer of 30.7 ft matches it.
| Watershed Area (acres) | 1.50 |
| Contributing Area to BMP (ac) | 1.50 |
| Watershed Non-DCIA Curve Number (0-100) | 80 |
| Watershed DCIA Percent (%) | 50.00 |
| Rainfall Zone | Florida Zone 3 |
| Rainfall (in) | 54.00 |
| Provided Nitrogen Treatment Efficiency (%) | 45.0 |
| Provided Phosphorus Treatment Efficiency (%) | 25.0 |
| Average Annual Recharge (MG/yr) | 0.00 |
| TN Mass Load (kg/yr) | 2.17 |
| TN Concentration (mg/L) | 0.00 |
| TP Mass Load (kg/yr) | 0.17 |
| TP Concentration (mg/L) | 0.00 |
Runoff input is only from this catchment, no routing is performed here
| Load N: 4.82 kg/yr P: 0.67 kg/yr Q: 3.13 ac-ft/yr |
→ |
Treatment N: 45 % P: 25 % |
→ |
Surface Discharge N: 2.65 kg/yr P: 0.50 kg/yr Q: 3.13 ac-ft/yr |
↓ |
||||
| Mass Reduction N: 2.17 kg/yr P: 0.17 kg/yr |