| Retention or Detention + Plants | Retention |
| Buffer Width (ft) | 50.00 |
| Buffer Length (ft) | 600.00 |
| Buffer Depth (ft) | 1.00 |
| Width of Area Feeding Buffer (ft) | 145.00 |
| Water storage capacity of soil (in/in) | 0.20 |
| Slope of Buffer (%) | 2.00 |
| Runoff Area (Width of Area Feeding Buffer x Length) (acres) | 1.997 |
| Buffer Area (Width x Length) (acres) | 0.689 |
| Contributing Area (Runoff Area + Buffer Area) (acres) | 2.686 |
| Watershed Area (acres) | 2.00 |
| Treatment Volume (ac-ft) | 0.138 |
| Treatment Depth (in) | 0.62 |
Warning: the Contributing Area (Runoff Area + Buffer Area) is 2.686 acres, but the catchment's area (Watershed Area, from 1. Enter Catchment) is 2.000 acres. They must be equal (within 1 %): the catchment is the area that drains to the buffer plus the buffer itself. The loads come from the catchment's area; the treatment is calculated from these dimensions. With this length and width, a Width of Area Feeding Buffer of 95.2 ft matches it; that also changes the Treatment Depth and so the removal, so Calculate again and check them.
| Watershed Area (acres) | 2.00 |
| Contributing Area to BMP (ac) | 2.00 |
| Watershed Non-DCIA Curve Number (0-100) | 75 |
| Watershed DCIA Percent (%) | 20.00 |
| Rainfall Zone | Florida Zone 2 |
| Rainfall (in) | 50.00 |
| Provided Nitrogen Treatment Efficiency (%) | 75.7 |
| Provided Phosphorus Treatment Efficiency (%) | 75.7 |
| Average Annual Recharge (MG/yr) | 0.00 |
| TN Mass Load (kg/yr) | 3.10 |
| TN Concentration (mg/L) | 0.00 |
| TP Mass Load (kg/yr) | 0.57 |
| TP Concentration (mg/L) | 0.00 |
Runoff input is only from this catchment, no routing is performed here
| Load N: 4.09 kg/yr P: 0.76 kg/yr Q: 1.88 ac-ft/yr |
→ |
Treatment N: 76 % P: 76 % |
→ |
Surface Discharge N: 0.99 kg/yr P: 0.18 kg/yr Q: 0.46 ac-ft/yr |
↓ |
||||
| Mass Reduction N: 3.10 kg/yr P: 0.57 kg/yr |