| Watershed Area (acres) | 40.00 |
| Contributing Area to BMP (ac) | 40.00 |
| Watershed Non-DCIA Curve Number (0-100) | 75 |
| Watershed DCIA Percent (%) | 25.00 |
| Rainfall Zone | Florida Zone 4 |
| Rainfall (in) | 52.00 |
| Provided Nitrogen Treatment Efficiency (%) | 0.0 |
| Provided Phosphorus Treatment Efficiency (%) | 0.0 |
| Average Annual Recharge (MG/yr) | 0.00 |
| TN Mass Load (kg/yr) | 0.00 |
| TN Concentration (mg/L) | 0.00 |
| TP Mass Load (kg/yr) | 0.00 |
| TP Concentration (mg/L) | 0.00 |
Runoff input is only from this catchment, no routing is performed here
| Load N: 104.78 kg/yr P: 19.36 kg/yr Q: 48.01 ac-ft/yr |
→ |
Treatment N: 0 % P: 0 % |
→ |
Surface Discharge N: 104.78 kg/yr P: 19.36 kg/yr Q: 48.01 ac-ft/yr |
↓ |
||||
| Mass Reduction N: 0.00 kg/yr P: 0.00 kg/yr |