Project: Example Problem # 3
Date: 10/16/2026
Discount Rate: 3.3%
Project Duration: 30 years
catchment 1 — Retention
| Component Name | Const. Low ($) | Const. High ($) | Service Life (yr) | O&M % Low | O&M % High | Annual O&M Low ($) | Annual O&M High ($) | Repl. Low (current $) | Repl. High (current $) | # Replacements | Repl. at Time of Replacement Low ($) | Repl. at Time of Replacement High ($) | PV Repl. Low ($) | PV Repl. High ($) | PV O&M Low ($) | PV O&M High ($) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Retention | $100,000 | $150,000 | 20 | 1.0000 | 6.0000 | $1,000 | $9,000 | $100,000 | $150,000 | 1 | $163,862 | $245,792 | $85,599 | $128,399 | $18,862 | $169,755 |
| Outlet Structure, Fixed | $10,000 | $15,000 | 60 | 0.0300 | 0.4000 | $3 | $60 | $10,000 | $15,000 | 0 | $0 | $0 | $0 | $0 | $57 | $1,132 |
| TOTALS | $110,000 | $165,000 | $1,003 | $9,060 | $85,599 | $128,399 | $18,918 | $170,887 |
Replacement costs. A replacement cost is entered as the current cost (today's dollars, a present value); a blank replacement cost uses the construction cost. The cost at the time of each replacement (future value) is estimated with the inflation rate (2.5%): FV = Replacement Cost × (1 + inflation)k × Life, for replacements k = 1, 2, … that fall before the end of the 30-year analysis period (a component whose life is equal to or longer than the period is not replaced). Each future value is discounted to today with the discount rate (3.3%): PV = FV / (1 + discount)k × Life. PV of Replacement is the sum of those present values.
catchment 1 — Retention
| Description | Unit | Quantity | $/Unit Low | $/Unit High | Annual Low ($) | Annual High ($) | PV Low ($) | PV High ($) |
|---|---|---|---|---|---|---|---|---|
| Mowing / Vegetation Control / Litter Removal | each | 2.00 | $1,850.00 | $1,850.00 | $3,700 | $3,700 | $69,788 | $69,788 |
| TOTALS | $3,700 | $3,700 | $69,788 | $69,788 | ||||