Summary Treatment Report: Specified Removal Efficiency
Catchments and Associated BMP Types
| ID |
Catchment Name |
Catchment BMP |
Routing Destination |
| 1 |
catchment 1 |
Retention |
Routed to Outlet |
Volume of Runoff Summary
| Scenario |
Catchment Area (acres) |
Runoff Volume (ac-ft/yr) |
Runoff Volume (in/year) |
| Pre-Condition |
11.00 |
1.01 |
1.10 |
| System Post-Condition (with BMPs) |
11.00 |
2.82 |
3.07 |
| Post-Condition (no BMP) |
11.00 |
11.28 |
12.30 |
Runoff volumes are shown in acre-feet per year and converted to depth (inches/year) by dividing by area and multiplying by 12.
The catchment area is the same in both post rows: BMPs do not change the area, only how much runoff leaves it. Post-Condition (no BMP) is all the runoff the post-development catchments produce; System Post-Condition (with BMPs) is the runoff that leaves the system at the outlet. BMPs that keep water out of the surface discharge (retention, exfiltration, harvesting and the like) make the with-BMP volume smaller; BMPs that discharge to surface water (wet detention, surface discharge filtration) remove nutrient load but not volume, so the two volumes can be equal.
Summary of Removals
Summary Loading:
|
Specified (for Specified Removal Efficiency) |
TN = 75.00%; |
TP = 75.00% |
|
Provided |
TN = 75.01%; |
TP = 75.01% |
% Specified Removal:
Is specified removal for total nitrogen removal met?
Yes
Is specified removal for total phosphorus removal met?
Yes
Results are compared against the analysis type targets. Percentages are shown to two decimals.
No Pre/Post Analysis
Analysis Type: Specified Removal Efficiency
There are no pre/post targets for this analysis type.
Nitrogen & Phosphorus Loading
Surface water and groundwater loading summary
| Nitrogen (N) |
| Total N pre load | 3.77 kg/yr |
| Total N post load | 24.61 kg/yr |
| Target N load reduction | 75.00 % |
| Target N discharge load | 6.15 kg/yr |
| Percent N load reduction | 75.01 % |
| Provided N discharge load | 6.15 kg/yr (13.56 lb/yr) |
| Provided N load removed (surface) | 18.46 kg/yr (40.70 lb/yr) |
| Phosphorus (P) |
| Total P pre load | 0.737 kg/yr |
| Total P post load | 4.546 kg/yr |
| Target P load reduction | 75.00 % |
| Target P discharge load | 1.136 kg/yr |
| Percent P load reduction | 75.01 % |
| Provided P discharge load | 1.136 kg/yr (2.505 lb/yr) |
| Provided P load removed (surface) | 3.410 kg/yr (7.518 lb/yr) |
Values are project totals. Surface units = kg/yr; groundwater recharge in MG/yr and concentrations in mg/L. Values formatted to appropriate precision.