Exfiltration System Input Variables

Pipe Span (in)48.00
Pipe Rise (in)48.00
Pipe Length (ft)600.00
Trench/Vault Width (ft)8.00
Trench Depth (ft)6.00
Trench Length (ft)600.00
Void Ratio (fraction)0.35
Pipe Volume (cf)7,539.82
Trench/Vault Volume (cf)7,441.06
Treatment Volume (ac-ft)0.34
Treatment Depth (in over CA)0.83
Treatment Depth (in)0.83
Time to Recover Design Volume (hr)72.00

Watershed Characteristics

Watershed Area (acres)5.00
Contributing Area to BMP (ac)5.00
Watershed Non-DCIA Curve Number (0-100)75
Watershed DCIA Percent (%)25.00
Rainfall ZoneFlorida Zone 1
Rainfall (in)62.00

Surface Water Discharge

Provided Nitrogen Treatment Efficiency (%)70.8
Provided Phosphorus Treatment Efficiency (%)70.8


Groundwater Discharge (Stand-Alone)

Average Annual Recharge (MG/yr)0.00
TN Mass Load (kg/yr)12.09
TN Concentration (mg/L)0.00
TP Mass Load (kg/yr)2.23
TP Concentration (mg/L)0.00



Surface Discharge Load Diagram for Exfiltration (stand-alone)

Runoff input is only from this catchment, no routing is performed here

Load
N: 17.08 kg/yr
P: 3.16 kg/yr
Q: 7.83 ac-ft/yr
→
Treatment
N: 71 %
P: 71 %
→
Surface Discharge
N: 4.99 kg/yr
P: 0.92 kg/yr
Q: 2.29 ac-ft/yr
↓
Mass Reduction
N: 12.09 kg/yr
P: 2.23 kg/yr