Exfiltration — Equations

Equations

Pipe Volume (cf) = pi x (Pipe Span / 24) x (Pipe Rise / 24) x Pipe Length
Trench Volume (cf) = (Trench Width x Trench Depth x Trench Length - Pipe Volume) x Void Ratio
Treatment Volume (ac-ft) = (Pipe Volume + Trench Volume) / 43560
Treatment Depth (in) = Treatment Volume / Contributing Area (ac) x 12

Notes

Values

VariableCurrent value
Pipe Span48.00 in
Pipe Rise48.00 in
Pipe Length600.00 ft
Trench Length600.00 ft
Trench/Vault Width8.00 ft
Trench Depth6.00 ft
Void Ratio0.35 fraction
Contributing Area5.000 ac
Watershed Area5.000 ac
Non-DCIA Curve Number75
DCIA Percent25 %
Rainfall ZoneFlorida Zone 1
Treatment Depth0.825 in
Hydraulic Capture70.8 %
Treatment Rate(no media mix)
N removal70.8 %
P removal70.8 %

Recovery-Time Adjustment

The efficiency from the retention lookup tables is raised by an adjustment that depends on the Treatment Depth and on how quickly the design volume is recovered.

Equations
x = Treatment Depth (in), T = Time to Recover Design Volume (hr)
T <= 3 hr: Adjustment (%) = -0.1365 x^4 + 1.5228 x^3 - 5.0475 x^2 + 2.3674 x + 8.8133
3 < T <= 36 hr: Adjustment (%) = 0.0083 x^4 - 0.1518 x^3 + 1.0071 x^2 - 3.0705 x + 3.7676
Hydraulic Capture (%) = Lookup Table Capture (%) + Adjustment
N removal (%) = P removal (%) = Lookup Table Capture (%) + Adjustment
Notes
VariableCurrent value
Time to Recover Design Volume (T)72 hr
Treatment Depth (x)0.825 in
Curve usedT > 36 hr: no adjustment
Recovery Time Adjustment0.00 %