Exfiltration System Input Variables

Pipe Span (in)36.00
Pipe Rise (in)36.00
Pipe Length (ft)300.00
Trench/Vault Width (ft)6.00
Trench Depth (ft)5.00
Trench Length (ft)300.00
Void Ratio (fraction)0.40
Pipe Volume (cf)2,120.58
Trench/Vault Volume (cf)2,751.77
Treatment Volume (ac-ft)0.11
Treatment Depth (in over CA)0.67
Treatment Depth (in)0.67
Time to Recover Design Volume (hr)72.00

Watershed Characteristics

Watershed Area (acres)2.00
Contributing Area to BMP (ac)2.00
Watershed Non-DCIA Curve Number (0-100)80
Watershed DCIA Percent (%)70.00
Rainfall ZoneFlorida Zone 3
Rainfall (in)54.00

Surface Water Discharge

Provided Nitrogen Treatment Efficiency (%)59.6
Provided Phosphorus Treatment Efficiency (%)59.6


Groundwater Discharge (Stand-Alone)

Average Annual Recharge (MG/yr)0.00
TN Mass Load (kg/yr)9.46
TN Concentration (mg/L)0.00
TP Mass Load (kg/yr)1.36
TP Concentration (mg/L)0.00



Surface Discharge Load Diagram for Exfiltration (stand-alone)

Runoff input is only from this catchment, no routing is performed here

Load
N: 15.87 kg/yr
P: 2.28 kg/yr
Q: 5.36 ac-ft/yr
→
Treatment
N: 60 %
P: 60 %
→
Surface Discharge
N: 6.41 kg/yr
P: 0.92 kg/yr
Q: 2.17 ac-ft/yr
↓
Mass Reduction
N: 9.46 kg/yr
P: 1.36 kg/yr