Exfiltration — Equations
Equations
Pipe Volume (cf) = pi x (Pipe Span / 24) x (Pipe Rise / 24) x Pipe Length
Trench Volume (cf) = (Trench Width x Trench Depth x Trench Length - Pipe Volume) x Void Ratio
Treatment Volume (ac-ft) = (Pipe Volume + Trench Volume) / 43560
Treatment Depth (in) = Treatment Volume / Contributing Area (ac) x 12
Notes
- Hydraulic capture efficiency is read from the retention efficiency lookup tables for the Treatment Depth.
- The lookup also depends on the watershed's non-DCIA curve number, DCIA percent and rainfall zone.
- N and P removal are equal to the hydraulic capture efficiency.
- A recovery-time adjustment for Time to Recover Design Volume is added to the capture efficiency and to N and P removal (see Recovery-Time Adjustment).
Values
| Variable | Current value |
| Pipe Span | 36.00 in |
| Pipe Rise | 36.00 in |
| Pipe Length | 300.00 ft |
| Trench Length | 300.00 ft |
| Trench/Vault Width | 6.00 ft |
| Trench Depth | 5.00 ft |
| Void Ratio | 0.40 fraction |
| Contributing Area | 2.000 ac |
| Watershed Area | 2.000 ac |
| Non-DCIA Curve Number | 80 |
| DCIA Percent | 70 % |
| Rainfall Zone | Florida Zone 3 |
| Treatment Depth | 0.671 in |
| Hydraulic Capture | 59.6 % |
| Treatment Rate | (no media mix) |
| N removal | 59.6 % |
| P removal | 59.6 % |
Recovery-Time Adjustment
The efficiency from the retention lookup tables is raised by an adjustment that depends on the Treatment Depth and on how quickly the design volume is recovered.
Equations
x = Treatment Depth (in), T = Time to Recover Design Volume (hr)
T <= 3 hr: Adjustment (%) = -0.1365 x^4 + 1.5228 x^3 - 5.0475 x^2 + 2.3674 x + 8.8133
3 < T <= 36 hr: Adjustment (%) = 0.0083 x^4 - 0.1518 x^3 + 1.0071 x^2 - 3.0705 x + 3.7676
Hydraulic Capture (%) = Lookup Table Capture (%) + Adjustment
N removal (%) = P removal (%) = Lookup Table Capture (%) + Adjustment
Notes
- No adjustment is made when T is not entered (0) or is greater than 36 hours.
- A negative adjustment is set to 0.
- N and P removal cannot exceed 100%.
| Variable | Current value |
| Time to Recover Design Volume (T) | 72 hr |
| Treatment Depth (x) | 0.671 in |
| Curve used | T > 36 hr: no adjustment |
| Recovery Time Adjustment | 0.00 % |