| Treatment Depth (in) | 0.50 |
| Hydraulic Capture Efficiency (%) | 71.50 |
| Type of Media Mix | B&G CTS12 |
| Media N Reduction (%) | 60.00 |
| Media P Reduction (%) | 90.00 |
| Watershed Area (acres) | 5.00 |
| Contributing Area to BMP (ac) | 5.00 |
| Watershed Non-DCIA Curve Number (0-100) | 75 |
| Watershed DCIA Percent (%) | 25.00 |
| Rainfall Zone | Florida Zone 2 |
| Rainfall (in) | 50.00 |
| Provided Nitrogen Treatment Efficiency (%) | 42.9 |
| Provided Phosphorus Treatment Efficiency (%) | 64.4 |
| Parameter | Value |
|---|---|
| Type of Media Mix | B&G CTS12 |
| Media N Reduction (%) | 60 |
| Media P Reduction (%) | 90 |
Note: Media Layer Depth not entered. B&G CTS12 needs at least 12 in (design guidance from the media suppliers; see the Media Mix help page). Enter the depth in Enter Media Mix Information to check it.
| Parameter | Value |
|---|---|
| Volume Filtered (MG/yr) | 1.272 |
| TN Load in the Filtered Water (kg/yr) | 3.407 |
| TN Concentration in the Filtered Water (mg/L) | 0.708 |
| TP Load in the Filtered Water (kg/yr) | 0.157 |
| TP Concentration in the Filtered Water (mg/L) | 0.033 |
The filtered water is discharged to the surface. The runoff the filter does not capture bypasses it untreated; the Surface Water Discharge table above shows the total leaving the BMP.
Runoff input is only from this catchment, no routing is performed here
| Load N: 11.91 kg/yr P: 2.20 kg/yr Q: 5.46 ac-ft/yr |
→ |
Treatment N: 43 % P: 64 % |
→ |
Surface Discharge N: 6.80 kg/yr P: 0.78 kg/yr Q: 1.56 ac-ft/yr |
↓ |
||||
| Mass Reduction N: 5.11 kg/yr P: 1.42 kg/yr |