Summary Treatment Report: BMP Analysis

Catchments and Associated BMP Types

ID Catchment Name Catchment BMP Routing Destination
1 Subdivision Filtration Routed to Outlet

Volume of Runoff Summary

Scenario Catchment Area (acres) Runoff Volume (ac-ft/yr) Runoff Volume (in/year)
System Post-Condition (with BMPs) 5.00 1.56 3.73
Post-Condition (no BMP) 5.00 5.46 13.10
Runoff volumes are shown in acre-feet per year and converted to depth (inches/year) by dividing by area and multiplying by 12.
The catchment area is the same in both post rows: BMPs do not change the area, only how much runoff leaves it. Post-Condition (no BMP) is all the runoff the post-development catchments produce; System Post-Condition (with BMPs) is the runoff that leaves the system at the outlet. BMPs that keep water out of the surface discharge (retention, exfiltration, harvesting and the like) make the with-BMP volume smaller; BMPs that discharge to surface water (wet detention, surface discharge filtration) remove nutrient load but not volume, so the two volumes can be equal.

Summary of Removals

No Specified % Removals
Analysis Type: BMP Analysis
There are no specified % removals defined for this analysis type.
Pre vs. Post Removals
System Removal for TN 42.9%
System Removal for TP 64.4%
Pre/Post comparisons use analysis-type settings to derive required reductions. Values shown to two decimals unless noted.
Nitrogen & Phosphorus Loading
Surface water and groundwater loading summary
Nitrogen (N)
Total N post load11.91 kg/yr
Percent N load reduction42.90 %
Provided N discharge load6.80 kg/yr (15.00 lb/yr)
Provided N load removed (surface)5.11 kg/yr (11.27 lb/yr)
Phosphorus (P)
Total P post load2.201 kg/yr
Percent P load reduction64.35 %
Provided P discharge load0.785 kg/yr (1.730 lb/yr)
Provided P load removed (surface)1.416 kg/yr (3.123 lb/yr)
Values are project totals. Surface units = kg/yr; groundwater recharge in MG/yr and concentrations in mg/L. Values formatted to appropriate precision.