Surface Discharge Filtration — Equations

Equations

Area Discharging to Filter (ac) = Contributing Area (ac) x (100 - Upstream Hydraulic Capture (%)) / 100
Treatment Depth (in) = Filter Surface Area (sf) x Rate (gpm/sf) / (18.85 x Area Discharging to Filter (ac))
18.85 = (43,560 sf/ac / 12 in/ft) / (0.0022288 cfs/gpm x 86,400 s/day): the depth of runoff, over the area discharging to the filter, that the media passes in one day
equivalently Minimum Filter Surface Area (sf) = Area Discharging to Filter (ac) x Treatment Depth (in) x 18.85 / Rate (gpm/sf)
Capture (%) = retention efficiency table lookup of Treatment Depth
Filter N removal (%) = Capture x Media N reduction / 100
Filter P removal (%) = Capture x Media P reduction / 100
Total N removal (%) = Upstream N + Filter N x (100 - Upstream N) / 100
Total P removal (%) = Upstream P + Filter P x (100 - Upstream P) / 100

Notes

Values

VariableCurrent value
Contributing Area3.000 ac
Watershed Area3.000 ac
Non-DCIA Curve Number80
DCIA Percent70 %
Rainfall ZoneFlorida Zone 3
Treatment Depth1.000 in
Hydraulic Capture71.1 %
Treatment Rate0.052 gpm/sf
N removal53.3 %
P removal67.5 %