| System Type | Retention |
| VFS Width (ft) | 20.00 |
| VFS Length (ft) | 400.00 |
| VFS Depth (ft) | 1.00 |
| Width of Area Feeding VFS (ft) | 109.00 |
| Water storage capacity of soil (in/in) | 0.20 |
| Slope of VFS (%) | 2.00 |
| Runoff Area (Width of Area Feeding VFS x Length) (acres) | 1.001 |
| VFS Area (Width x Length) (acres) | 0.184 |
| Contributing Area (Runoff Area + VFS Area) (acres) | 1.185 |
| Watershed Area (acres) | 1.00 |
| Treatment Volume (ac-ft) | 0.037 |
| Treatment Depth (in) | 0.37 |
Warning: the Contributing Area (Runoff Area + VFS Area) is 1.185 acres, but the catchment's area (Watershed Area, from 1. Enter Catchment) is 1.000 acres. They must be equal (within 1 %): the catchment is the area that drains to the VFS plus the VFS itself. The loads come from the catchment's area; the treatment is calculated from these dimensions. With this length and width, a Width of Area Feeding VFS of 88.9 ft matches it; that also changes the Treatment Depth and so the removal, so Calculate again and check them.
| Watershed Area (acres) | 1.00 |
| Contributing Area to BMP (ac) | 1.18 |
| Watershed Non-DCIA Curve Number (0-100) | 80 |
| Watershed DCIA Percent (%) | 60.00 |
| Rainfall Zone | Florida Zone 2 |
| Rainfall (in) | 50.00 |
| Provided Nitrogen Treatment Efficiency (%) | 46.5 |
| Provided Phosphorus Treatment Efficiency (%) | 46.5 |
| Average Annual Recharge (MG/yr) | 0.00 |
| TN Mass Load (kg/yr) | 1.18 |
| TN Concentration (mg/L) | 0.00 |
| TP Mass Load (kg/yr) | 0.24 |
| TP Concentration (mg/L) | 0.00 |
Runoff input is only from this catchment, no routing is performed here
| Load N: 2.53 kg/yr P: 0.52 kg/yr Q: 2.21 ac-ft/yr |
→ |
Treatment N: 47 % P: 47 % |
→ |
Surface Discharge N: 1.35 kg/yr P: 0.28 kg/yr Q: 1.18 ac-ft/yr |
↓ |
||||
| Mass Reduction N: 1.18 kg/yr P: 0.24 kg/yr |