Greenroof — Equations
Equations
Treatment Depth (in) = Cistern Storage (in over Greenroof Area)
No cistern (storage 0): Removal Efficiency (%) = c
With a cistern: Removal Efficiency (%) = max(c, a x ln(Cistern Storage) + b)
Irrigation Water Use (gal/yr) = Irrigation Demand (in/yr) / 12 x Greenroof Area (sf) x 7.48052 gal/cf
Harvested Water Supply (gal/yr) = Removal Efficiency / 100 x Rainfall Excess (in/yr) / 12 x Greenroof Area (sf) x 7.48052 gal/cf (0 with no cistern)
Supplemental Water Needed (gal/yr) = Irrigation Water Use - Harvested Water Supply (0 when the supply covers the use)
Notes
- Cistern Storage is entered directly; there is no depth derivation.
- a, b and c are the coefficients of the selected Rainfall Station; c is its removal with no cistern.
- A cistern never gives less removal than no cistern: below about 0.11-0.16 in the curve a x ln(storage) + b is lower than c, and c is used.
- N and P removal are equal.
- The water budget is calculated only when Irrigation Demand or Rainfall Excess is entered; it does not change the removal.
Values
| Variable | Current value |
| Greenroof Storage | 2.00 in over Greenroof Area |
| Contributing Area | 1.000 ac |
| Watershed Area | 1.000 ac |
| Non-DCIA Curve Number | 98 |
| DCIA Percent | 100 % |
| Rainfall Zone | Florida Zone 5 |
| Treatment Depth | 2.000 in |
| Hydraulic Capture | 69.1 % |
| Treatment Rate | (no media mix) |
| N removal | 69.1 % |
| P removal | 69.1 % |