Greenroof — Equations

Equations

Treatment Depth (in) = Cistern Storage (in over Greenroof Area)
No cistern (storage 0): Removal Efficiency (%) = c
With a cistern: Removal Efficiency (%) = max(c, a x ln(Cistern Storage) + b)
Irrigation Water Use (gal/yr) = Irrigation Demand (in/yr) / 12 x Greenroof Area (sf) x 7.48052 gal/cf
Harvested Water Supply (gal/yr) = Removal Efficiency / 100 x Rainfall Excess (in/yr) / 12 x Greenroof Area (sf) x 7.48052 gal/cf (0 with no cistern)
Supplemental Water Needed (gal/yr) = Irrigation Water Use - Harvested Water Supply (0 when the supply covers the use)

Notes

Values

VariableCurrent value
Greenroof Storage2.00 in over Greenroof Area
Contributing Area1.000 ac
Watershed Area1.000 ac
Non-DCIA Curve Number98
DCIA Percent100 %
Rainfall ZoneFlorida Zone 5
Treatment Depth2.000 in
Hydraulic Capture69.1 %
Treatment Rate(no media mix)
N removal69.1 %
P removal69.1 %