Retention Input Variables

Treatment Depth (in)1.20
Retention Volume (ac-ft)1.000
Time to Recover Design Volume (hr)72.00

Watershed Characteristics

Watershed Area (acres)10.00
Contributing Area to BMP (ac)10.00
Watershed Non-DCIA Curve Number (0-100)75
Watershed DCIA Percent (%)25.00
Rainfall ZoneFlorida Zone 2
Rainfall (in)50.00

Surface Water Discharge

Provided Nitrogen Treatment Efficiency (%)88.4
Provided Phosphorus Treatment Efficiency (%)88.4


Groundwater Discharge (Stand-Alone)

Average Annual Recharge (MG/yr)0.00
TN Mass Load (kg/yr)21.06
TN Concentration (mg/L)0.00
TP Mass Load (kg/yr)3.89
TP Concentration (mg/L)0.00



Surface Discharge Load Diagram for Retention (stand-alone)

Runoff input is only from this catchment, no routing is performed here

Load
N: 23.82 kg/yr
P: 4.40 kg/yr
Q: 10.92 ac-ft/yr
→
Treatment
N: 88 %
P: 88 %
→
Surface Discharge
N: 2.76 kg/yr
P: 0.51 kg/yr
Q: 1.27 ac-ft/yr
↓
Mass Reduction
N: 21.06 kg/yr
P: 3.89 kg/yr