Rainwater Harvesting — Equations

Equations

Equivalent Impervious Area EIA (sf) = Contributing Area (sf) x Roof Factor
Volume over EIA (in) = Harvest Volume (gal) / 7.4805 gal/cf / EIA (sf) x 12
Harvest Rate (cf/day) = Harvest Rate (in/week) x Irrigation Area (sf) / (7 x 12)
Rate over EIA (in/day) = 12 x Harvest Rate (cf/day) / EIA (sf)
Harvest Efficiency (%) = REV table lookup of (Volume over EIA, Rate over EIA)
Water Use (gal/yr) = Harvest Rate (in/week) x 52 / 12 x Irrigation Area (sf) x 7.48052 gal/cf
Harvested Water Supply (gal/yr) = Harvest Efficiency / 100 x EIA (sf) x Annual Rainfall (in) / 12 x 7.48052 gal/cf
Supplemental Water Needed (gal/yr) = Water Use - Harvested Water Supply (0 when the supply covers the use)

Notes

Values

VariableCurrent value
Total Area Available for Irrigation5,000.00 sf
Available Harvest Volume1,500.00 gallons
Available Harvest Rate1.00 in/week
Contributing Area3,049 sf
Watershed Area3,049 sf
Non-DCIA Curve Number98
DCIA Percent100 %
Rainfall ZoneFlorida Zone 2
Treatment Depth0.000 in
Hydraulic Capture76.2 %
Treatment Rate(no media mix)
N removal76.2 %
P removal76.2 %