Multiple BMP in Series — Equations

System case

Case type: Retention in Series. Calculation used: Retention in Series (one combined retention system).

Retention system (2 retention BMPs as one) [BMP 1 (Permeable Pavement) + BMP 2 (Retention)]

SegmentBMPsHow it is calculated
Retention system (2 retention BMPs as one)BMP 1 (Permeable Pavement) + BMP 2 (Retention)Treatment depths summed (Equivalent Treatment Depth); removal e from the retention lookup tables; e is the Multiple BMP's removal

Equations

Equivalent Treatment Depth (in) = sum of the Treatment Depths of the retention BMPs
Equivalent Treatment Efficiency e (%) = retention lookup (Equivalent Treatment Depth, non-DCIA CN, DCIA %, rainfall zone)
N removal = P removal = Hydraulic Capture = e

Notes

Values

VariableCurrent value
ScenarioRetention in Series
Calculation usedRetention in Series (one combined retention system)
Runoff into the series13.903 ac-ft/yr
N load into the series21.428 kg/yr
P load into the series2.966 kg/yr
Equivalent Treatment Depth1.411 in
Equivalent Treatment Efficiency (e)78.908 %
Hydraulic Capture78.9 %
N removal (Multiple BMP)78.9 %
P removal (Multiple BMP)78.9 %
N load out (surface discharge)4.52 kg/yr
P load out (surface discharge)0.626 kg/yr

Calculation steps (values as used)

#StepCalculation (values used)Result
1Inflow to the seriescatchment runoff and loadsQ 13.903 ac-ft/yr, N 21.428 kg/yr, P 2.966 kg/yr
2Equivalent Treatment DepthBMP 1 (Permeable Pavement) 0.66 in + BMP 2 (Retention) 0.751 in1.411 in
3Equivalent Treatment Efficiency (e)retention lookup at 1.411 in, non-DCIA CN 80, DCIA 60 %, Florida Zone 578.91 %
4Multiple BMP removalN = P = Hydraulic Capture = e78.91 %

BMP 1: Permeable Pavement

Part of the combined retention system: its Treatment Depth is added into the Equivalent Treatment Depth. Its own N and P removal below is not applied separately.

Equations
Storage (ac-ft) = Surface Area (ac) x Sum over layers [Layer Thickness (in) x Sustainable Void (%) / 100] x Layer Scale Factor / 12
Treatment Depth (in) = Storage / Watershed Area (ac) x 12
Notes
Values
VariableCurrent value
Contributing Area4.000 ac
Watershed Area5.000 ac
Non-DCIA Curve Number80
DCIA Percent60 %
Rainfall ZoneFlorida Zone 5
Treatment Depth0.660 in
Hydraulic Capture57.9 %
Treatment Rate(no media mix)
N removal57.9 %
P removal57.9 %
Recovery-Time Adjustment

The efficiency from the retention lookup tables is raised by an adjustment that depends on the Treatment Depth and on how quickly the design volume is recovered.

Equations
x = Treatment Depth (in), T = Time to Recover Design Volume (hr)
T <= 3 hr: Adjustment (%) = -0.1365 x^4 + 1.5228 x^3 - 5.0475 x^2 + 2.3674 x + 8.8133
3 < T <= 36 hr: Adjustment (%) = 0.0083 x^4 - 0.1518 x^3 + 1.0071 x^2 - 3.0705 x + 3.7676
Hydraulic Capture (%) = Lookup Table Capture (%) + Adjustment
N removal (%) = P removal (%) = Lookup Table Capture (%) + Adjustment
Notes
VariableCurrent value
Time to Recover Design Volume (T)72 hr
Treatment Depth (x)0.660 in
Curve usedT > 36 hr: no adjustment
Recovery Time Adjustment0.00 %

BMP 2: Retention

Part of the combined retention system: its Treatment Depth is added into the Equivalent Treatment Depth. Its own N and P removal below is not applied separately.

Equations
Treatment Depth (in) = Retention Volume (ac-ft) / Contributing Area (ac) x 12
Notes
Values
VariableCurrent value
Retention Volume0.313 ac-ft
Contributing Area5.000 ac
Watershed Area5.000 ac
Non-DCIA Curve Number80
DCIA Percent60 %
Rainfall ZoneFlorida Zone 5
Treatment Depth0.751 in
Hydraulic Capture62.1 %
Treatment Rate(no media mix)
N removal62.1 %
P removal62.1 %
Recovery-Time Adjustment

The efficiency from the retention lookup tables is raised by an adjustment that depends on the Treatment Depth and on how quickly the design volume is recovered.

Equations
x = Treatment Depth (in), T = Time to Recover Design Volume (hr)
T <= 3 hr: Adjustment (%) = -0.1365 x^4 + 1.5228 x^3 - 5.0475 x^2 + 2.3674 x + 8.8133
3 < T <= 36 hr: Adjustment (%) = 0.0083 x^4 - 0.1518 x^3 + 1.0071 x^2 - 3.0705 x + 3.7676
Hydraulic Capture (%) = Lookup Table Capture (%) + Adjustment
N removal (%) = P removal (%) = Lookup Table Capture (%) + Adjustment
Notes
VariableCurrent value
Time to Recover Design Volume (T)72 hr
Treatment Depth (x)0.751 in
Curve usedT > 36 hr: no adjustment
Recovery Time Adjustment0.00 %