Multiple BMP in Series — Equations
System case
Case type: Retention to Wet Detention. Calculation used: Retention to Wet Detention (combined retention system, routed).
Retention [BMP 1 (Retention)] → Routed wet detention [BMP 2 (Wet Detention)]
| Segment | BMPs | How it is calculated |
| Retention | BMP 1 (Retention) | Treatment depths summed (Equivalent Treatment Depth); removal e from the retention lookup tables |
| Routed wet detention | BMP 2 (Wet Detention) | Effective Residence Time from the volume the retention passes on; combined as e + (100 - e)(D/100 - a/100 x e/100), a = 10 (N), 20 (P) |
Equations
Equivalent Treatment Depth (in) = sum of the Treatment Depths of the retention BMPs
Equivalent Treatment Efficiency e (%) = retention lookup (Equivalent Treatment Depth, non-DCIA CN, DCIA %, rainfall zone)
Volume to pond (ac-ft/yr) = Runoff x (100 - e) / 100
Effective Residence Time (days) = Permanent Pool Volume (ac-ft) / Volume to pond (ac-ft/yr) x 365
D = the pond's removal at the Effective Residence Time
Pond series contribution (%) = (100 - e) x (D / 100 - a / 100 x e / 100), a = 10 for N, 20 for P (not below 0)
Removal (%) = e + pond series contribution
Notes
- The Multiple BMP detects its scenario from the BMPs in the series and uses the calculation named above.
- The steps table lists every calculation in the order it was made, with the values used.
- Each BMP's section shows its own equations and its values as they stand after the series calculation.
- When all upstream BMPs consist of Retention BMPs, the sum of the treatment depths are used to calculate efficiency. These are titled Equivalent Treatment Depth and Equivalent Treatment Efficiency.
- The wet detention is then applied to what this system passes on, which gives the treatment efficiency of the Multiple BMP.
Values
| Variable | Current value |
| Scenario | Retention to Wet Detention |
| Calculation used | Retention to Wet Detention (combined retention system, routed) |
| Runoff into the series | 13.903 ac-ft/yr |
| N load into the series | 21.428 kg/yr |
| P load into the series | 2.966 kg/yr |
| Equivalent Treatment Depth | 0.751 in |
| Equivalent Treatment Efficiency (e) | 62.139 % |
| Hydraulic Capture | 62.1 % |
| N removal (Multiple BMP) | 76.1 % |
| P removal (Multiple BMP) | 88.6 % |
| N load out (surface discharge) | 5.125 kg/yr |
| P load out (surface discharge) | 0.338 kg/yr |
Calculation steps (values as used)
| # | Step | Calculation (values used) | Result |
| 1 | Inflow to the series | catchment runoff and loads | Q 13.903 ac-ft/yr, N 21.428 kg/yr, P 2.966 kg/yr |
| 2 | Equivalent Treatment Depth | BMP 1 (Retention) 0.751 in | 0.751 in |
| 3 | Equivalent Treatment Efficiency (e) | retention lookup at 0.751 in, non-DCIA CN 80, DCIA 60 %, Florida Zone 5 | 62.14 % |
| 4 | Volume passed to the pond | 13.903 x (100 - 62.139) / 100 | 5.264 ac-ft/yr |
| 5 | Effective Residence Time | 3.809 ac-ft / 5.264 ac-ft/yr x 365 | 264.125 days |
| 6 | Pond removal D at that residence time | wet detention N and P equations | N 43.04 %, P 82.29 % |
| 7 | Pond series contribution | N: (100 - 62.139) x (43.036/100 - 10/100 x 62.139/100); P: (100 - 62.139) x (82.287/100 - 20/100 x 62.139/100) (not below 0) | N 13.94 %, P 26.45 % |
| 8 | Removal through the pond (e + pond contribution) | N: 62.139 + 13.941; P: 62.139 + 26.449 | N 76.08 %, P 88.59 % |
| 9 | Loads out of the retention system | load in x (100 - e) / 100 | N 8.113 kg/yr, P 1.123 kg/yr |
| 10 | Loads out of the Wet Detention | its load in, less its series contribution expressed on the flow reaching it | N 5.125 kg/yr, P 0.338 kg/yr |
BMP 1: Retention
Part of the combined retention system: its Treatment Depth is added into the Equivalent Treatment Depth. Its own N and P removal below is not applied separately.
Equations
Treatment Depth (in) = Retention Volume (ac-ft) / Contributing Area (ac) x 12
Notes
- Hydraulic capture efficiency is read from the retention efficiency lookup tables for the Treatment Depth.
- The lookup also depends on the watershed's non-DCIA curve number, DCIA percent and rainfall zone.
- N and P removal are equal to the hydraulic capture efficiency.
- A recovery-time adjustment for Time to Recover Design Volume is added to the capture efficiency and to N and P removal (see Recovery-Time Adjustment).
Values
| Variable | Current value |
| Retention Volume | 0.313 ac-ft |
| Contributing Area | 5.000 ac |
| Watershed Area | 5.000 ac |
| Non-DCIA Curve Number | 80 |
| DCIA Percent | 60 % |
| Rainfall Zone | Florida Zone 5 |
| Treatment Depth | 0.751 in |
| Hydraulic Capture | 62.1 % |
| Treatment Rate | (no media mix) |
| N removal | 62.1 % |
| P removal | 62.1 % |
Recovery-Time Adjustment
The efficiency from the retention lookup tables is raised by an adjustment that depends on the Treatment Depth and on how quickly the design volume is recovered.
Equations
x = Treatment Depth (in), T = Time to Recover Design Volume (hr)
T <= 3 hr: Adjustment (%) = -0.1365 x^4 + 1.5228 x^3 - 5.0475 x^2 + 2.3674 x + 8.8133
3 < T <= 36 hr: Adjustment (%) = 0.0083 x^4 - 0.1518 x^3 + 1.0071 x^2 - 3.0705 x + 3.7676
Hydraulic Capture (%) = Lookup Table Capture (%) + Adjustment
N removal (%) = P removal (%) = Lookup Table Capture (%) + Adjustment
Notes
- No adjustment is made when T is not entered (0) or is greater than 36 hours.
- A negative adjustment is set to 0.
- N and P removal cannot exceed 100%.
| Variable | Current value |
| Time to Recover Design Volume (T) | 72 hr |
| Treatment Depth (x) | 0.751 in |
| Curve used | T > 36 hr: no adjustment |
| Recovery Time Adjustment | 0.00 % |
BMP 2: Wet Detention
Receives what the retention system passes on; its residence time is re-derived from that volume (see the steps above).
Equations
Residence Time rt (days) = Permanent Pool Volume (ac-ft) / Annual Runoff Volume (ac-ft) x 365
N removal (%) = 43.75 x rt / (4.38 + rt)
P removal (%) = 40.13 + 6.372 x ln(rt) + 0.213 x [ln(rt)]^2
No littoral zone: N removal = N removal x 0.90, P removal = P removal x 0.90
Wetland credit: N removal = N removal + Wetland Efficiency Credit x (100 - N removal) / 100
P removal = P removal + Wetland Efficiency Credit x (100 - P removal) / 100
Notes
- Residence Time is capped at 200 days unless ART > 200 is allowed.
- The littoral-zone reduction is applied before the wetland credit.
- N and P removal cannot exceed 100%.
Values
| Variable | Current value |
| Wetland Efficiency Credit | 0.00 % |
| Permanent Pool Volume | 3.81 ac-ft |
| Annual Runoff Volume | 13.90 ac-ft |
| Treatment Rate | (no media mix) |
| N removal | 43.0 % |
| P removal | 82.3 % |
| Effective Residence Time (routed) | 264.125 days |
| Pond N removal at that residence time | 43.036 % |
| Pond P removal at that residence time | 82.287 % |
| N series contribution | 13.941 % |
| P series contribution | 26.449 % |