Multiple BMP in Series

Watershed Characteristics

Watershed Area (acres)6.00
Contributing Area to BMP (ac)6.00
Watershed Non-DCIA Curve Number (0-100)85
Watershed DCIA Percent (%)65.00
Rainfall ZoneFlorida Zone 2
Rainfall (in)51.00

BMP in Series Number: 1 (BMP Type: Tree Well)

Vegetated Area (Tree Well) depth (ft)4.00
Tree Well Storage (above media + canopy capture) (ft)2.00
Vegetated Area (Tree Well) Length (ft)5.00
Vegetated Area (Tree Well) Width (ft)5.00
Sustainable water storage capacity of the soil (ft)0.25
Number of Similar Areas in Watershed40
Treatment Volume (ac-ft)0.098
Treatment Depth (in)0.20
Retention or DetentionRetention

BMP in Series Number: 2 (BMP Type: Exfiltration)

Pipe Span (in)48.00
Pipe Rise (in)48.00
Pipe Length (ft)200.00
Trench/Vault Width (ft)5.00
Trench Depth (ft)4.50
Trench Length (ft)200.00
Void Ratio (fraction)0.25
Pipe Volume (cf)2,513.27
Trench/Vault Volume (cf)496.68
Treatment Volume (ac-ft)0.07
Treatment Depth (in over CA)0.14
Treatment Depth (in)0.14
Time to Recover Design Volume (hr)72.00

BMP in Series Number: 3 (BMP Type: Retention)

Treatment Depth (in)1.00
Retention Volume (ac-ft)0.500
Time to Recover Design Volume (hr)72.00
Provided Nitrogen Treatment Efficiency (%)75.9
Provided Phosphorus Treatment Efficiency (%)75.9

Equivalent Treatment Depth and Efficiency (Retention in Series)

When all upstream BMPs consist of Retention BMPs, the sum of the treatment depths are used to calculate efficiency. These are titled Equivalent Treatment Depth and Equivalent Treatment Efficiency.

There is no downstream BMP in this series, so this efficiency is also the treatment efficiency of the Multiple BMP.

Parameter Value
Equivalent Treatment Depth (in) 1.333
Equivalent Treatment Efficiency (%) 83.300
Multiple BMP Provided N Treatment Efficiency (%) 83
Multiple BMP Provided P Treatment Efficiency (%) 83

Surface Water Discharge

Provided Nitrogen Treatment Efficiency (%)83.3
Provided Phosphorus Treatment Efficiency (%)83.3


Load for Multiple BMP in Series


Load
N: 17.02 kg/yr
P: 3.44 kg/yr
Q: 14.84 ac-ft/yr
→Treatment
N: 83 %
P: 83 %
Q: 83 %
→Surface Discharge
N: 2.84 kg/yr
P: 0.57 kg/yr
Q: 2.48 ac-ft/yr
↓
Mass Reduction
N: 14.18 kg/yr
P: 2.87 kg/yr
Q: 12.36 ac-ft/yr