Multiple BMP in Series — Equations

System case

Case type: Retention in Series. Calculation used: Retention in Series (one combined retention system).

Retention system (3 retention BMPs as one) [BMP 1 (Tree Well) + BMP 2 (Exfiltration) + BMP 3 (Retention)]

SegmentBMPsHow it is calculated
Retention system (3 retention BMPs as one)BMP 1 (Tree Well) + BMP 2 (Exfiltration) + BMP 3 (Retention)Treatment depths summed (Equivalent Treatment Depth); removal e from the retention lookup tables; e is the Multiple BMP's removal

Equations

Equivalent Treatment Depth (in) = sum of the Treatment Depths of the retention BMPs
Equivalent Treatment Efficiency e (%) = retention lookup (Equivalent Treatment Depth, non-DCIA CN, DCIA %, rainfall zone)
N removal = P removal = Hydraulic Capture = e

Notes

Values

VariableCurrent value
ScenarioRetention in Series
Calculation usedRetention in Series (one combined retention system)
Runoff into the series14.841 ac-ft/yr
N load into the series17.018 kg/yr
P load into the series3.44 kg/yr
Equivalent Treatment Depth1.333 in
Equivalent Treatment Efficiency (e)83.3 %
Hydraulic Capture83.3 %
N removal (Multiple BMP)83.3 %
P removal (Multiple BMP)83.3 %
N load out (surface discharge)2.842 kg/yr
P load out (surface discharge)0.575 kg/yr

Calculation steps (values as used)

#StepCalculation (values used)Result
1Inflow to the seriescatchment runoff and loadsQ 14.841 ac-ft/yr, N 17.018 kg/yr, P 3.44 kg/yr
2Equivalent Treatment DepthBMP 1 (Tree Well) 0.195 in + BMP 2 (Exfiltration) 0.138 in + BMP 3 (Retention) 1 in1.333 in
3Equivalent Treatment Efficiency (e)retention lookup at 1.333 in, non-DCIA CN 85, DCIA 65 %, Florida Zone 283.3 %
4Multiple BMP removalN = P = Hydraulic Capture = e83.3 %

BMP 1: Tree Well retention

Part of the combined retention system: its Treatment Depth is added into the Equivalent Treatment Depth. Its own N and P removal below is not applied separately.

Equations
Storage per Area (ac-ft) = Length x Width x (Depth + Soil Storage Capacity) / 43560
Treatment Volume (ac-ft) = Storage per Area x Number of Similar Areas
Treatment Depth (in) = Treatment Volume / Watershed Area (ac) x 12
Notes
Values
VariableCurrent value
Vegetated Area (Tree Well) depth4.00 ft
Vegetated Area (Tree Well) Length5.00 ft
Vegetated Area (Tree Well) Width5.00 ft
Sustainable water storage capacity of the soil0.25 ft
Number of Similar Areas in Watershed40
Contributing Area6.000 ac
Watershed Area6.000 ac
Non-DCIA Curve Number85
DCIA Percent65 %
Rainfall ZoneFlorida Zone 2
Treatment Depth0.195 in
Hydraulic Capture26.3 %
Treatment Rate(no media mix)
N removal26.3 %
P removal26.3 %

BMP 2: Exfiltration

Part of the combined retention system: its Treatment Depth is added into the Equivalent Treatment Depth. Its own N and P removal below is not applied separately.

Equations
Pipe Volume (cf) = pi x (Pipe Span / 24) x (Pipe Rise / 24) x Pipe Length
Trench Volume (cf) = (Trench Width x Trench Depth x Trench Length - Pipe Volume) x Void Ratio
Treatment Volume (ac-ft) = (Pipe Volume + Trench Volume) / 43560
Treatment Depth (in) = Treatment Volume / Contributing Area (ac) x 12
Notes
Values
VariableCurrent value
Pipe Span48.00 in
Pipe Rise48.00 in
Pipe Length200.00 ft
Trench Length200.00 ft
Trench/Vault Width5.00 ft
Trench Depth4.50 ft
Void Ratio0.25 fraction
Contributing Area6.000 ac
Watershed Area6.000 ac
Non-DCIA Curve Number85
DCIA Percent65 %
Rainfall ZoneFlorida Zone 2
Treatment Depth0.138 in
Hydraulic Capture18.6 %
Treatment Rate(no media mix)
N removal18.6 %
P removal18.6 %
Recovery-Time Adjustment

The efficiency from the retention lookup tables is raised by an adjustment that depends on the Treatment Depth and on how quickly the design volume is recovered.

Equations
x = Treatment Depth (in), T = Time to Recover Design Volume (hr)
T <= 3 hr: Adjustment (%) = -0.1365 x^4 + 1.5228 x^3 - 5.0475 x^2 + 2.3674 x + 8.8133
3 < T <= 36 hr: Adjustment (%) = 0.0083 x^4 - 0.1518 x^3 + 1.0071 x^2 - 3.0705 x + 3.7676
Hydraulic Capture (%) = Lookup Table Capture (%) + Adjustment
N removal (%) = P removal (%) = Lookup Table Capture (%) + Adjustment
Notes
VariableCurrent value
Time to Recover Design Volume (T)72 hr
Treatment Depth (x)0.138 in
Curve usedT > 36 hr: no adjustment
Recovery Time Adjustment0.00 %

BMP 3: Retention

Part of the combined retention system: its Treatment Depth is added into the Equivalent Treatment Depth. Its own N and P removal below is not applied separately.

Equations
Treatment Depth (in) = Retention Volume (ac-ft) / Contributing Area (ac) x 12
Notes
Values
VariableCurrent value
Retention Volume0.500 ac-ft
Contributing Area6.000 ac
Watershed Area6.000 ac
Non-DCIA Curve Number85
DCIA Percent65 %
Rainfall ZoneFlorida Zone 2
Treatment Depth1.000 in
Hydraulic Capture75.9 %
Treatment Rate(no media mix)
N removal75.9 %
P removal75.9 %
Recovery-Time Adjustment

The efficiency from the retention lookup tables is raised by an adjustment that depends on the Treatment Depth and on how quickly the design volume is recovered.

Equations
x = Treatment Depth (in), T = Time to Recover Design Volume (hr)
T <= 3 hr: Adjustment (%) = -0.1365 x^4 + 1.5228 x^3 - 5.0475 x^2 + 2.3674 x + 8.8133
3 < T <= 36 hr: Adjustment (%) = 0.0083 x^4 - 0.1518 x^3 + 1.0071 x^2 - 3.0705 x + 3.7676
Hydraulic Capture (%) = Lookup Table Capture (%) + Adjustment
N removal (%) = P removal (%) = Lookup Table Capture (%) + Adjustment
Notes
VariableCurrent value
Time to Recover Design Volume (T)72 hr
Treatment Depth (x)1.000 in
Curve usedT > 36 hr: no adjustment
Recovery Time Adjustment0.00 %