Multiple BMP in Series — Equations
System case
Case type: Retention in Series. Calculation used: Retention in Series (one combined retention system).
Retention system (3 retention BMPs as one) [BMP 1 (Tree Well) + BMP 2 (Exfiltration) + BMP 3 (Retention)]
| Segment | BMPs | How it is calculated |
| Retention system (3 retention BMPs as one) | BMP 1 (Tree Well) + BMP 2 (Exfiltration) + BMP 3 (Retention) | Treatment depths summed (Equivalent Treatment Depth); removal e from the retention lookup tables; e is the Multiple BMP's removal |
Equations
Equivalent Treatment Depth (in) = sum of the Treatment Depths of the retention BMPs
Equivalent Treatment Efficiency e (%) = retention lookup (Equivalent Treatment Depth, non-DCIA CN, DCIA %, rainfall zone)
N removal = P removal = Hydraulic Capture = e
Notes
- The Multiple BMP detects its scenario from the BMPs in the series and uses the calculation named above.
- The steps table lists every calculation in the order it was made, with the values used.
- Each BMP's section shows its own equations and its values as they stand after the series calculation.
- When all upstream BMPs consist of Retention BMPs, the sum of the treatment depths are used to calculate efficiency. These are titled Equivalent Treatment Depth and Equivalent Treatment Efficiency.
- There is no downstream BMP in this series, so this efficiency is also the treatment efficiency of the Multiple BMP.
Values
| Variable | Current value |
| Scenario | Retention in Series |
| Calculation used | Retention in Series (one combined retention system) |
| Runoff into the series | 14.841 ac-ft/yr |
| N load into the series | 17.018 kg/yr |
| P load into the series | 3.44 kg/yr |
| Equivalent Treatment Depth | 1.333 in |
| Equivalent Treatment Efficiency (e) | 83.3 % |
| Hydraulic Capture | 83.3 % |
| N removal (Multiple BMP) | 83.3 % |
| P removal (Multiple BMP) | 83.3 % |
| N load out (surface discharge) | 2.842 kg/yr |
| P load out (surface discharge) | 0.575 kg/yr |
Calculation steps (values as used)
| # | Step | Calculation (values used) | Result |
| 1 | Inflow to the series | catchment runoff and loads | Q 14.841 ac-ft/yr, N 17.018 kg/yr, P 3.44 kg/yr |
| 2 | Equivalent Treatment Depth | BMP 1 (Tree Well) 0.195 in + BMP 2 (Exfiltration) 0.138 in + BMP 3 (Retention) 1 in | 1.333 in |
| 3 | Equivalent Treatment Efficiency (e) | retention lookup at 1.333 in, non-DCIA CN 85, DCIA 65 %, Florida Zone 2 | 83.3 % |
| 4 | Multiple BMP removal | N = P = Hydraulic Capture = e | 83.3 % |
BMP 1: Tree Well retention
Part of the combined retention system: its Treatment Depth is added into the Equivalent Treatment Depth. Its own N and P removal below is not applied separately.
Equations
Storage per Area (ac-ft) = Length x Width x (Depth + Soil Storage Capacity) / 43560
Treatment Volume (ac-ft) = Storage per Area x Number of Similar Areas
Treatment Depth (in) = Treatment Volume / Watershed Area (ac) x 12
Notes
- Hydraulic capture efficiency is read from the retention efficiency lookup tables for the Treatment Depth.
- The lookup also depends on the watershed's non-DCIA curve number, DCIA percent and rainfall zone.
- N and P removal are equal to the hydraulic capture efficiency.
Values
| Variable | Current value |
| Vegetated Area (Tree Well) depth | 4.00 ft |
| Vegetated Area (Tree Well) Length | 5.00 ft |
| Vegetated Area (Tree Well) Width | 5.00 ft |
| Sustainable water storage capacity of the soil | 0.25 ft |
| Number of Similar Areas in Watershed | 40 |
| Contributing Area | 6.000 ac |
| Watershed Area | 6.000 ac |
| Non-DCIA Curve Number | 85 |
| DCIA Percent | 65 % |
| Rainfall Zone | Florida Zone 2 |
| Treatment Depth | 0.195 in |
| Hydraulic Capture | 26.3 % |
| Treatment Rate | (no media mix) |
| N removal | 26.3 % |
| P removal | 26.3 % |
BMP 2: Exfiltration
Part of the combined retention system: its Treatment Depth is added into the Equivalent Treatment Depth. Its own N and P removal below is not applied separately.
Equations
Pipe Volume (cf) = pi x (Pipe Span / 24) x (Pipe Rise / 24) x Pipe Length
Trench Volume (cf) = (Trench Width x Trench Depth x Trench Length - Pipe Volume) x Void Ratio
Treatment Volume (ac-ft) = (Pipe Volume + Trench Volume) / 43560
Treatment Depth (in) = Treatment Volume / Contributing Area (ac) x 12
Notes
- Hydraulic capture efficiency is read from the retention efficiency lookup tables for the Treatment Depth.
- The lookup also depends on the watershed's non-DCIA curve number, DCIA percent and rainfall zone.
- N and P removal are equal to the hydraulic capture efficiency.
- A recovery-time adjustment for Time to Recover Design Volume is added to the capture efficiency and to N and P removal (see Recovery-Time Adjustment).
Values
| Variable | Current value |
| Pipe Span | 48.00 in |
| Pipe Rise | 48.00 in |
| Pipe Length | 200.00 ft |
| Trench Length | 200.00 ft |
| Trench/Vault Width | 5.00 ft |
| Trench Depth | 4.50 ft |
| Void Ratio | 0.25 fraction |
| Contributing Area | 6.000 ac |
| Watershed Area | 6.000 ac |
| Non-DCIA Curve Number | 85 |
| DCIA Percent | 65 % |
| Rainfall Zone | Florida Zone 2 |
| Treatment Depth | 0.138 in |
| Hydraulic Capture | 18.6 % |
| Treatment Rate | (no media mix) |
| N removal | 18.6 % |
| P removal | 18.6 % |
Recovery-Time Adjustment
The efficiency from the retention lookup tables is raised by an adjustment that depends on the Treatment Depth and on how quickly the design volume is recovered.
Equations
x = Treatment Depth (in), T = Time to Recover Design Volume (hr)
T <= 3 hr: Adjustment (%) = -0.1365 x^4 + 1.5228 x^3 - 5.0475 x^2 + 2.3674 x + 8.8133
3 < T <= 36 hr: Adjustment (%) = 0.0083 x^4 - 0.1518 x^3 + 1.0071 x^2 - 3.0705 x + 3.7676
Hydraulic Capture (%) = Lookup Table Capture (%) + Adjustment
N removal (%) = P removal (%) = Lookup Table Capture (%) + Adjustment
Notes
- No adjustment is made when T is not entered (0) or is greater than 36 hours.
- A negative adjustment is set to 0.
- N and P removal cannot exceed 100%.
| Variable | Current value |
| Time to Recover Design Volume (T) | 72 hr |
| Treatment Depth (x) | 0.138 in |
| Curve used | T > 36 hr: no adjustment |
| Recovery Time Adjustment | 0.00 % |
BMP 3: Retention
Part of the combined retention system: its Treatment Depth is added into the Equivalent Treatment Depth. Its own N and P removal below is not applied separately.
Equations
Treatment Depth (in) = Retention Volume (ac-ft) / Contributing Area (ac) x 12
Notes
- Hydraulic capture efficiency is read from the retention efficiency lookup tables for the Treatment Depth.
- The lookup also depends on the watershed's non-DCIA curve number, DCIA percent and rainfall zone.
- N and P removal are equal to the hydraulic capture efficiency.
- A recovery-time adjustment for Time to Recover Design Volume is added to the capture efficiency and to N and P removal (see Recovery-Time Adjustment).
Values
| Variable | Current value |
| Retention Volume | 0.500 ac-ft |
| Contributing Area | 6.000 ac |
| Watershed Area | 6.000 ac |
| Non-DCIA Curve Number | 85 |
| DCIA Percent | 65 % |
| Rainfall Zone | Florida Zone 2 |
| Treatment Depth | 1.000 in |
| Hydraulic Capture | 75.9 % |
| Treatment Rate | (no media mix) |
| N removal | 75.9 % |
| P removal | 75.9 % |
Recovery-Time Adjustment
The efficiency from the retention lookup tables is raised by an adjustment that depends on the Treatment Depth and on how quickly the design volume is recovered.
Equations
x = Treatment Depth (in), T = Time to Recover Design Volume (hr)
T <= 3 hr: Adjustment (%) = -0.1365 x^4 + 1.5228 x^3 - 5.0475 x^2 + 2.3674 x + 8.8133
3 < T <= 36 hr: Adjustment (%) = 0.0083 x^4 - 0.1518 x^3 + 1.0071 x^2 - 3.0705 x + 3.7676
Hydraulic Capture (%) = Lookup Table Capture (%) + Adjustment
N removal (%) = P removal (%) = Lookup Table Capture (%) + Adjustment
Notes
- No adjustment is made when T is not entered (0) or is greater than 36 hours.
- A negative adjustment is set to 0.
- N and P removal cannot exceed 100%.
| Variable | Current value |
| Time to Recover Design Volume (T) | 72 hr |
| Treatment Depth (x) | 1.000 in |
| Curve used | T > 36 hr: no adjustment |
| Recovery Time Adjustment | 0.00 % |