Stormwater Harvesting — Equations

Equations

x = Harvest Volume (ac-ft) x 12 / (Watershed Area (ac) x ROC)
y = Harvest Rate (in/week) x Irrigation Area (ac) / 7 / (Watershed Area (ac) x ROC)
Harvest Efficiency (%) = REV table lookup of (x, y)
Water Use (MGY) = Harvest Rate (in/week) x 52 / 12 x Irrigation Area (ac) x 0.32585 MG/ac-ft
Harvested Water Supply (MGY) = Annual Runoff Volume (ac-ft/yr) x Harvest Efficiency / 100 x 0.32585 MG/ac-ft
Supplemental Water Needed (MGY) = Water Use - Harvested Water Supply (0 when the supply covers the use)

Notes

Values

VariableCurrent value
Available Harvest Volume1.00 ac-ft
Total Area Available for Irrigation3.00 acres
Available Harvest Rate0.80 in/week
Contributing Area5.000 ac
Watershed Area5.000 ac
Non-DCIA Curve Number80
DCIA Percent70 %
Rainfall ZoneFlorida Zone 5
Treatment Depth0.809 in
Hydraulic Capture62.0 %
Treatment Rate(no media mix)
N removal62.0 %
P removal62.0 %