Swale — Equations
Equations
Rainfall Excess Area (ac) = (W x L + Impervious L x Impervious W) / 43560
Flow in Swale (cfs) = Rainfall Excess Area x Rainfall Intensity (rainfall zone)
Depth of Flow d: solved from Manning, Q = 1.486/n x A x R^(2/3) x S^(1/2)
A = B d + Z d^2, P = B + 2 d sqrt(Z^2 + 1), R = A / P
Infiltrated Depth (in) = [L x Infiltration Rate x P / (12 x 3600)] x 6000 x 12 / (Rainfall Excess Area x 43560)
Swale Block Storage (cf) = (w x H / 6) x (sl - Lb) x Nb, w = B + 2 Z H, sl = min(H / S, L / Nb)
Block Depth (in) = 12 x Swale Block Storage / (Rainfall Excess Area x 43560)
Treatment Depth (in) = min(4, Infiltrated Depth + Block Depth)
Treatment Volume (ac-ft) = Treatment Depth x Rainfall Excess Area / 12
Notes
- Hydraulic capture efficiency is read from the retention efficiency lookup tables for the Treatment Depth.
- The lookup also depends on the watershed's non-DCIA curve number, DCIA percent and rainfall zone.
- N and P removal are equal to the hydraulic capture efficiency.
- If the Average Pervious Width is less than W, W is used.
Values
| Variable | Current value |
| Swale Top Width for Flood Conditions - W | 20.00 ft |
| Swale Bottom Width - B | 4.00 ft |
| Swale Length - L | 1,000.00 ft |
| Average Impervious Length | 1,000.00 ft |
| Average Impervious Width | 36.00 ft |
| Average Pervious Width | 84.00 ft |
| Swale Slope (foot drop/foot length) - S | 0.005 |
| Mannings N | 0.200 |
| Soil Infiltration Rate | 2.00 in/hr |
| Side Slope of Swale horizontal/vertical - Z | 4.00 |
| Average Height of Swale Block - H | 0.50 ft |
| Length of Berm Upstream of Crest - Lb | 10.00 ft |
| Number of Swale Blocks | 8 |
| Contributing Area | 2.750 ac |
| Watershed Area | 2.750 ac |
| Non-DCIA Curve Number | 80 |
| DCIA Percent | 45 % |
| Rainfall Zone | Florida Zone 2 |
| Treatment Depth | 0.466 in |
| Hydraulic Capture | 59.7 % |
| Treatment Rate | (no media mix) |
| N removal | 59.7 % |
| P removal | 59.7 % |