| User Defined BMP | Baffle Boxes 2nd Gen |
| Contributing Area to BMP (ac) | 10.00 |
| Calculated Nitrogen Treatment Efficiency (as entered) (%) | 19.00 |
| Calculated Phosphorus Treatment Efficiency (as entered) (%) | 35.00 |
| Watershed Area (acres) | 10.00 |
| Contributing Area to BMP (ac) | 10.00 |
| Watershed Non-DCIA Curve Number (0-100) | 75 |
| Watershed DCIA Percent (%) | 25.00 |
| Rainfall Zone | Florida Zone 2 |
| Rainfall (in) | 50.00 |
| Provided Nitrogen Treatment Efficiency (%) | 19.0 |
| Provided Phosphorus Treatment Efficiency (%) | 35.0 |
| Average Annual Recharge (MG/yr) | 0.00 |
| TN Mass Load (kg/yr) | 0.00 |
| TN Concentration (mg/L) | 0.00 |
| TP Mass Load (kg/yr) | 0.00 |
| TP Concentration (mg/L) | 0.00 |
Runoff input is only from this catchment, no routing is performed here
| Load N: 23.82 kg/yr P: 4.40 kg/yr Q: 10.92 ac-ft/yr |
→ |
Treatment N: 19 % P: 35 % |
→ |
Surface Discharge N: 19.30 kg/yr P: 2.86 kg/yr Q: 7.10 ac-ft/yr |
↓ |
||||
| Mass Reduction N: 4.53 kg/yr P: 1.54 kg/yr |