| Retention or Detention + Plants | Retention |
| Buffer Width | 50.00 ft |
| Buffer Length | 600.00 ft |
| Buffer Depth | 1.00 ft |
| Width of Area Feeding Buffer | 145.00 ft |
| Water storage capacity of soil | 0.20 in/in |
| Slope of Buffer | 2.00 % |
| Runoff Area (Width of Area Feeding Buffer x Length) | 1.997 acres |
| Buffer Area (Width x Length) | 0.689 acres |
| Contributing Area (Runoff Area + Buffer Area) | 2.686 acres |
| Watershed Area | 2.00 acres |
| Treatment Volume | 0.138 ac-ft |
| Treatment Depth | 0.62 in |
Warning: the Contributing Area (Runoff Area + Buffer Area) is 2.686 acres, but the catchment's area (Watershed Area, from 1. Enter Catchment) is 2.000 acres. They must be equal (within 1 %): the catchment is the area that drains to the buffer plus the buffer itself. The loads come from the catchment's area; the treatment is calculated from these dimensions. With this length and width, a Width of Area Feeding Buffer of 95.2 ft matches it; that also changes the Treatment Depth and so the removal, so Calculate again and check them.
| Watershed Area | 2.00 acres |
| Contributing Area to BMP | 2.00 ac |
| Watershed Non-DCIA Curve Number (0-100) | 75 |
| Watershed DCIA Percent | 20.00 % |
| Rainfall Zone | Florida Zone 2 |
| Rainfall | 50.00 in |
| Provided Nitrogen Treatment Efficiency | 75.7 % |
| Provided Phosphorus Treatment Efficiency | 75.7 % |
| Average Annual Recharge | 0.00 MG/yr |
| TN Mass Load | 3.10 kg/yr |
| TN Concentration | 0.00 mg/L |
| TP Mass Load | 0.57 kg/yr |
| TP Concentration | 0.00 mg/L |
Runoff input is only from this catchment, no routing is performed here
| N | 4.09 kg/yr |
| P | 0.76 kg/yr |
| Q | 1.88 ac-ft/yr |
| N | 76 % |
| P | 76 % |
| N | 0.99 kg/yr |
| P | 0.18 kg/yr |
| Q | 0.46 ac-ft/yr |
| N | 3.10 kg/yr |
| P | 0.57 kg/yr |
| Q | 1.42 ac-ft/yr |
The equations behind the values above, and the values they are worked with (v1's Equations page).
Treatment Volume (ac-ft) = Buffer Width x Buffer Length x Buffer Depth x Soil Storage Capacity / 43560
Treatment Depth (in) = 12 in/ft x Buffer Width x Buffer Depth x Soil Storage Capacity / (Buffer Width + Width of Area Feeding Buffer)
Hydraulic Capture (%) = retention curves (Treatment Depth, non-DCIA CN, DCIA %, rainfall zone)
N removal (%) = P removal (%) = Hydraulic Capture
Retention: Hydraulic capture efficiency is read from the retention efficiency lookup tables for the Treatment Depth.
The lookup also depends on the watershed's non-DCIA curve number, DCIA percent and rainfall zone.
The buffer tables are not used.
| Variable | Current value |
|---|---|
| Buffer Width | 50.00 ft |
| Buffer Length | 600.00 ft |
| Buffer Depth | 1.00 ft |
| Width of Area Feeding Buffer | 145.00 ft |
| Water storage capacity of soil | 0.20 in/in |
| Slope of Buffer | 2.00 % |
| Contributing Area | 2.000 ac |
| Watershed Area | 2.000 ac |
| Non-DCIA Curve Number | 75 |
| DCIA Percent | 20 % |
| Rainfall Zone | Florida Zone 2 |
| Treatment Depth | 0.615 in |
| Hydraulic Capture | 75.7 % |
| Treatment Rate | (no media mix) |
| N removal | 75.7 % |
| P removal | 75.7 % |