| Watershed Area | 5.00 acres |
| Contributing Area to BMP | 5.00 ac |
| Watershed Non-DCIA Curve Number (0-100) | 80 |
| Watershed DCIA Percent | 85.00 % |
| Rainfall Zone | Florida Zone 5 |
| Rainfall | 61.00 in |
| Permanent Pool Volume | 2.47 ac-ft |
| Permanent Pool Volume for 31 days residence | 1.53 ac-ft |
| Average Residence Time | 50.00 days |
| Has Littoral Zone | Yes |
| Wetland Efficiency Credit | 10.00 % |
| Contributing Area to BMP | 5.00 ac |
| Total Area Available for Irrigation | 3.00 acres |
| Available Harvest Volume | 1.00 ac-ft |
| Available Harvest Rate | 0.80 in/week |
| Effective Impervious Area | 3.55 acres |
| Treatment Depth | 0.67 in |
| Provided Nitrogen Treatment Efficiency | 78.8 % |
| Provided Phosphorus Treatment Efficiency | 90.8 % |
| Load N: 27.81 kg/yr P: 3.85 kg/yr Q: 18.05 ac-ft/yr | → | Treatment N: 79 % P: 91 % Q: 53 % | → | Surface Discharge N: 5.89 kg/yr P: 0.36 kg/yr Q: 8.54 ac-ft/yr |
| ↓ | ||||
| Mass Reduction N: 21.92 kg/yr P: 3.49 kg/yr Q: 9.51 ac-ft/yr |
The equations behind the values above, and the values they are worked with (v1's Equations page).
Case type: Wet Detention to Stormwater Harvesting. Calculation used: Wet Detention to Stormwater Harvesting.
Wet detention [BMP 1 (Wet Detention)] → Treatment train (stormwater harvesting) [BMP 2 (Stormwater Harvesting)]
| Segment | BMPs | How it is calculated |
|---|---|---|
| Wet detention | BMP 1 (Wet Detention) | Its own removal |
| Treatment train (stormwater harvesting) | BMP 2 (Stormwater Harvesting) | Added to the removal so far: E = E1 + E2(1 - E1/100); its removal also sets the hydraulic capture |
Treatment train: E (%) = E1 + E2 x (1 - E1 / 100)
Applied to each BMP in turn
Hydraulic Capture (%) = the last harvesting / downstream BMP's N removal
The Multiple BMP detects its scenario from the BMPs in the series and uses the calculation named above.
The steps table lists every calculation in the order it was made, with the values used.
Each BMP's section shows its own equations and its values as they stand after the series calculation.
| Variable | Current value |
|---|---|
| Scenario | Wet Detention to Stormwater Harvesting |
| Calculation used | Wet Detention to Stormwater Harvesting |
| Runoff into the series | 18.046 ac-ft/yr |
| N load into the series | 27.813 kg/yr |
| P load into the series | 3.849 kg/yr |
| Hydraulic Capture | 52.7 % |
| N removal (Multiple BMP) | 78.8 % |
| P removal (Multiple BMP) | 90.8 % |
| N load out (surface discharge) | 5.894 kg/yr |
| P load out (surface discharge) | 0.355 kg/yr |
| # | Step | Calculation (values used) | Result |
|---|---|---|---|
| 1 | Inflow to the series | catchment runoff and loads | Q 18.046 ac-ft/yr, N 27.813 kg/yr, P 3.849 kg/yr |
| 2 | Combine BMP 1 and BMP 2 | N: 55.204 + 52.691 x (1 - 55.204/100); P: 80.485 + 52.691 x (1 - 80.485/100) | N 78.81 %, P 90.77 % |
| 3 | Hydraulic Capture | = BMP 2 (harvesting) N removal | 52.69 % |
Its N and P removal below is combined with the rest of the series as shown in the steps above.
Equations
Residence Time rt (days) = Permanent Pool Volume (ac-ft) / Annual Runoff Volume (ac-ft) x 365
N removal (%) = 43.75 x rt / (4.38 + rt)
P removal (%) = 40.13 + 6.372 x ln(rt) + 0.213 x [ln(rt)]^2
Littoral zone: N removal = N removal + Littoral Zone Credit, P removal = P removal + Littoral Zone Credit (credit 0 to 10 %; none without one)
Wetland credit: N removal = N removal + Wetland Efficiency Credit x (100 - N removal) / 100
P removal = P removal + Wetland Efficiency Credit x (100 - P removal) / 100
Notes
Residence Time is capped at 200 days unless ART > 200 is allowed.
The littoral zone credit is added before the wetland credit (BMPFast 2: the equations are a pond without a littoral zone).
N and P removal cannot exceed 100%.
Values
| Variable | Current value |
|---|---|
| Wetland Efficiency Credit | 10.00 % |
| Permanent Pool Volume | 2.47 ac-ft |
| Annual Runoff Volume | 18.05 ac-ft |
| Treatment Rate | (no media mix) |
| N removal | 55.2 % |
| P removal | 80.5 % |
Its N and P removal below is combined with the rest of the series as shown in the steps above.
Equations
x = Harvest Volume (ac-ft) x 12 / (Watershed Area (ac) x ROC)
y = Harvest Rate (in/week) x Irrigation Area (ac) / 7 / (Watershed Area (ac) x ROC)
Harvest Efficiency (%) = REV table lookup of (x, y)
Water Use (MGY) = Harvest Rate (in/week) x 52 / 12 x Irrigation Area (ac) x 0.32585 MG/ac-ft
Harvested Water Supply (MGY) = Annual Runoff Volume (ac-ft/yr) x Harvest Efficiency / 100 x 0.32585 MG/ac-ft
Supplemental Water Needed (MGY) = Water Use - Harvested Water Supply (0 when the supply covers the use)
Notes
ROC is the catchment's annual runoff coefficient.
Harvest Efficiency is capped at 90%. Below 20%, the lowest REV curve, it is extended along the line between the 20% and 30% curves (beyond the published curves).
N and P removal are equal to the Harvest Efficiency.
Treatment Depth is back-calculated as the retention depth giving the same efficiency in the retention tables.
Values: the harvest efficiency is read from the REV curves of the Rainfall Zone. Non-DCIA Curve Number, DCIA Percent and Treatment Rate are listed for every retention-type BMP but are not used to calculate the harvest efficiency. Non-DCIA Curve Number and DCIA Percent are used only to back-calculate the Treatment Depth.
Values
| Variable | Current value |
|---|---|
| Available Harvest Volume | 1.00 ac-ft |
| Total Area Available for Irrigation | 3.00 acres |
| Available Harvest Rate | 0.80 in/week |
| Contributing Area | 5.000 ac |
| Watershed Area | 5.000 ac |
| Non-DCIA Curve Number | 80 |
| DCIA Percent | 85 % |
| Rainfall Zone | Florida Zone 5 |
| Treatment Depth | 0.672 in |
| Hydraulic Capture | 52.7 % |
| Treatment Rate | (no media mix) |
| N removal | 52.7 % |
| P removal | 52.7 % |