Routing 1, at a discount rate of 3.30 % over 30 years.
Project: Example Problem # 3 Date: 10/20/2026
Discount Rate: 3.3% Project Duration: 30 years
catchment 1 — Retention
| Component Name | Const. Low ($) | Const. High ($) | Service Life (yr) | O&M % Low | O&M % High | Annual O&M Low ($) | Annual O&M High ($) | Repl. Low (current $) | Repl. High (current $) | # Replacements | Repl. at Time of Replacement Low ($) | Repl. at Time of Replacement High ($) | PV Repl. Low ($) | PV Repl. High ($) | PV O&M Low ($) | PV O&M High ($) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Retention | ¤100,000 | ¤150,000 | 20 | 1.0000 | 6.0000 | ¤1,000 | ¤9,000 | ¤100,000 | ¤150,000 | 1 | ¤163,862 | ¤245,792 | ¤85,599 | ¤128,399 | ¤18,862 | ¤169,755 |
| Outlet Structure, Fixed | ¤10,000 | ¤15,000 | 60 | 0.0300 | 0.4000 | ¤3 | ¤60 | ¤10,000 | ¤15,000 | 0 | ¤0 | ¤0 | ¤0 | ¤0 | ¤57 | ¤1,132 |
| TOTALS | ¤110,000 | ¤165,000 | ¤1,003 | ¤9,060 | ¤85,599 | ¤128,399 | ¤18,918 | ¤170,887 |
Replacement costs. A replacement cost is entered as the current cost (today's dollars, a present value); a blank replacement cost uses the construction cost. The cost at the time of each replacement (future value) is estimated with the inflation rate (2.5%): FV = Replacement Cost × (1 + inflation)k × Life, for replacements k = 1, 2, … that fall before the end of the 30-year analysis period (a component whose life is equal to or longer than the period is not replaced). Each future value is discounted to today with the discount rate (3.3%): PV = FV / (1 + discount)k × Life. PV of Replacement is the sum of those present values.
catchment 1 — Retention
| Description | Unit | Quantity | $/Unit Low | $/Unit High | Annual Low ($) | Annual High ($) | PV Low ($) | PV High ($) |
|---|---|---|---|---|---|---|---|---|
| Mowing / Vegetation Control / Litter Removal | each | 2.00 | ¤1,850.00 | ¤1,850.00 | ¤3,700 | ¤3,700 | ¤69,788 | ¤69,788 |
| TOTALS | ¤3,700 | ¤3,700 | ¤69,788 | ¤69,788 |