How this treatment's values are worked out: the equations, then the values they are worked with (v1's Equations button). A change on the Entry or Sizing tab shows here at once.
Case type: Retention to Wet Detention. Calculation used: Retention to Wet Detention (combined retention system, routed).
Retention [BMP 1 (Retention)] → Routed wet detention [BMP 2 (Wet Detention)]
| Segment | BMPs | How it is calculated |
|---|---|---|
| Retention | BMP 1 (Retention) | Treatment depths summed (Equivalent Treatment Depth); removal e from the retention lookup tables |
| Routed wet detention | BMP 2 (Wet Detention) | Effective Residence Time from the volume the retention passes on; combined as e + (100 - e)(D/100 - a/100 x e/100), a = 10 (N), 20 (P) |
Equivalent Treatment Depth (in) = sum of the Treatment Depths of the retention BMPs
Equivalent Treatment Efficiency e (%) = retention lookup (Equivalent Treatment Depth, non-DCIA CN, DCIA %, rainfall zone)
Volume to pond (ac-ft/yr) = Runoff x (100 - e) / 100
Effective Residence Time (days) = Permanent Pool Volume (ac-ft) / Volume to pond (ac-ft/yr) x 365
D = the pond's removal at the Effective Residence Time
Pond series contribution (%) = (100 - e) x (D / 100 - a / 100 x e / 100), a = 10 for N, 20 for P (not below 0)
Removal (%) = e + pond series contribution
The Multiple BMP detects its scenario from the BMPs in the series and uses the calculation named above.
The steps table lists every calculation in the order it was made, with the values used.
Each BMP's section shows its own equations and its values as they stand after the series calculation.
When all upstream BMPs consist of Retention BMPs, the sum of the treatment depths are used to calculate efficiency. These are titled Equivalent Treatment Depth and Equivalent Treatment Efficiency.
The wet detention is then applied to what this system passes on, which gives the treatment efficiency of the Multiple BMP.
| Variable | Current value |
|---|---|
| Scenario | Retention to Wet Detention |
| Calculation used | Retention to Wet Detention (combined retention system, routed) |
| Runoff into the series | 13.903 ac-ft/yr |
| N load into the series | 21.428 kg/yr |
| P load into the series | 2.966 kg/yr |
| Equivalent Treatment Depth | 0.751 in |
| Equivalent Treatment Efficiency (e) | 62.139 % |
| Hydraulic Capture | 62.1 % |
| N removal (Multiple BMP) | 79.9 % |
| P removal (Multiple BMP) | 92.4 % |
| N load out (surface discharge) | 4.314 kg/yr |
| P load out (surface discharge) | 0.226 kg/yr |
| # | Step | Calculation (values used) | Result |
|---|---|---|---|
| 1 | Inflow to the series | catchment runoff and loads | Q 13.903 ac-ft/yr, N 21.428 kg/yr, P 2.966 kg/yr |
| 2 | Equivalent Treatment Depth | BMP 1 (Retention) 0.751 in | 0.751 in |
| 3 | Equivalent Treatment Efficiency (e) | retention lookup at 0.751 in, non-DCIA CN 80, DCIA 60 %, Florida Zone 5 | 62.14 % |
| 4 | Volume passed to the pond | 13.903 x (100 - 62.139) / 100 | 5.264 ac-ft/yr |
| 5 | Effective Residence Time | 3.809 ac-ft / 5.264 ac-ft/yr x 365 | 264.125 days |
| 6 | Pond removal D at that residence time | wet detention N and P equations, + 10 points (littoral zone credit) | N 53.04 %, P 92.29 % |
| 7 | Pond series contribution | N: (100 - 62.139) x (53.036/100 - 10/100 x 62.139/100); P: (100 - 62.139) x (92.287/100 - 20/100 x 62.139/100) (not below 0) | N 17.73 %, P 30.23 % |
| 8 | Removal through the pond (e + pond contribution) | N: 62.139 + 17.727; P: 62.139 + 30.235 | N 79.87 %, P 92.37 % |
| 9 | Loads out of the retention system | load in x (100 - e) / 100 | N 8.113 kg/yr, P 1.123 kg/yr |
| 10 | Loads out of the Wet Detention | its load in, less its series contribution expressed on the flow reaching it | N 4.314 kg/yr, P 0.226 kg/yr |
Part of the combined retention system: its Treatment Depth is added into the Equivalent Treatment Depth. Its own N and P removal below is not applied separately.
Equations
Treatment Depth (in) = Retention Volume (ac-ft) / Contributing Area (ac) x 12
Notes
Hydraulic capture efficiency is read from the retention efficiency lookup tables for the Treatment Depth.
The lookup also depends on the watershed's non-DCIA curve number, DCIA percent and rainfall zone.
N and P removal are equal to the hydraulic capture efficiency.
Values
| Variable | Current value |
|---|---|
| Retention Volume | 0.313 ac-ft |
| Contributing Area | 5.000 ac |
| Watershed Area | 5.000 ac |
| Non-DCIA Curve Number | 80 |
| DCIA Percent | 60 % |
| Rainfall Zone | Florida Zone 5 |
| Treatment Depth | 0.751 in |
| Hydraulic Capture | 62.1 % |
| Treatment Rate | (no media mix) |
| N removal | 62.1 % |
| P removal | 62.1 % |
Receives what the retention system passes on; its residence time is re-derived from that volume (see the steps above).
Equations
Residence Time rt (days) = Permanent Pool Volume (ac-ft) / Annual Runoff Volume (ac-ft) x 365
N removal (%) = 43.75 x rt / (4.38 + rt)
P removal (%) = 40.13 + 6.372 x ln(rt) + 0.213 x [ln(rt)]^2
Littoral zone: N removal = N removal + Littoral Zone Credit, P removal = P removal + Littoral Zone Credit (credit 0 to 10 %; none without one)
Wetland credit: N removal = N removal + Wetland Efficiency Credit x (100 - N removal) / 100
P removal = P removal + Wetland Efficiency Credit x (100 - P removal) / 100
Notes
Residence Time is capped at 200 days unless ART > 200 is allowed.
The littoral zone credit is added before the wetland credit (BMPFast 2: the equations are a pond without a littoral zone).
N and P removal cannot exceed 100%.
Values
| Variable | Current value |
|---|---|
| Wetland Efficiency Credit | 0.00 % |
| Permanent Pool Volume | 3.81 ac-ft |
| Annual Runoff Volume | 13.90 ac-ft |
| Treatment Rate | (no media mix) |
| N removal | 53.0 % |
| P removal | 92.3 % |
| Effective Residence Time (routed) | 264.125 days |
| Pond N removal at that residence time | 43.036 % |
| Pond P removal at that residence time | 92.374 % |
| N series contribution | 17.727 % |
| P series contribution | 30.235 % |