BMPs in Series — calculations

Ex # 5 ret to det one catch — BMPs in Series on Highway Section 206 (stand-alone: this catchment's runoff only)
Made by BMPFast 2 on Tuesday, 20 October 2026 16:00

How this treatment's values are worked out: the equations, then the values they are worked with (v1's Equations button). A change on the Entry or Sizing tab shows here at once.

System case

Case type: Retention to Wet Detention. Calculation used: Retention to Wet Detention (combined retention system, routed).

Retention [BMP 1 (Retention)] → Routed wet detention [BMP 2 (Wet Detention)]

SegmentBMPsHow it is calculated
RetentionBMP 1 (Retention)Treatment depths summed (Equivalent Treatment Depth); removal e from the retention lookup tables
Routed wet detentionBMP 2 (Wet Detention)Effective Residence Time from the volume the retention passes on; combined as e + (100 - e)(D/100 - a/100 x e/100), a = 10 (N), 20 (P)

Equations

Equivalent Treatment Depth (in) = sum of the Treatment Depths of the retention BMPs

Equivalent Treatment Efficiency e (%) = retention lookup (Equivalent Treatment Depth, non-DCIA CN, DCIA %, rainfall zone)

Volume to pond (ac-ft/yr) = Runoff x (100 - e) / 100

Effective Residence Time (days) = Permanent Pool Volume (ac-ft) / Volume to pond (ac-ft/yr) x 365

D = the pond's removal at the Effective Residence Time

Pond series contribution (%) = (100 - e) x (D / 100 - a / 100 x e / 100), a = 10 for N, 20 for P (not below 0)

Removal (%) = e + pond series contribution

Notes

The Multiple BMP detects its scenario from the BMPs in the series and uses the calculation named above.

The steps table lists every calculation in the order it was made, with the values used.

Each BMP's section shows its own equations and its values as they stand after the series calculation.

When all upstream BMPs consist of Retention BMPs, the sum of the treatment depths are used to calculate efficiency. These are titled Equivalent Treatment Depth and Equivalent Treatment Efficiency.

The wet detention is then applied to what this system passes on, which gives the treatment efficiency of the Multiple BMP.

Values

VariableCurrent value
ScenarioRetention to Wet Detention
Calculation usedRetention to Wet Detention (combined retention system, routed)
Runoff into the series13.903 ac-ft/yr
N load into the series21.428 kg/yr
P load into the series2.966 kg/yr
Equivalent Treatment Depth0.751 in
Equivalent Treatment Efficiency (e)62.139 %
Hydraulic Capture62.1 %
N removal (Multiple BMP)79.9 %
P removal (Multiple BMP)92.4 %
N load out (surface discharge)4.314 kg/yr
P load out (surface discharge)0.226 kg/yr

Calculation steps (values as used)

#StepCalculation (values used)Result
1Inflow to the seriescatchment runoff and loadsQ 13.903 ac-ft/yr, N 21.428 kg/yr, P 2.966 kg/yr
2Equivalent Treatment DepthBMP 1 (Retention) 0.751 in0.751 in
3Equivalent Treatment Efficiency (e)retention lookup at 0.751 in, non-DCIA CN 80, DCIA 60 %, Florida Zone 562.14 %
4Volume passed to the pond13.903 x (100 - 62.139) / 1005.264 ac-ft/yr
5Effective Residence Time3.809 ac-ft / 5.264 ac-ft/yr x 365264.125 days
6Pond removal D at that residence timewet detention N and P equations, + 10 points (littoral zone credit)N 53.04 %, P 92.29 %
7Pond series contributionN: (100 - 62.139) x (53.036/100 - 10/100 x 62.139/100); P: (100 - 62.139) x (92.287/100 - 20/100 x 62.139/100) (not below 0)N 17.73 %, P 30.23 %
8Removal through the pond (e + pond contribution)N: 62.139 + 17.727; P: 62.139 + 30.235N 79.87 %, P 92.37 %
9Loads out of the retention systemload in x (100 - e) / 100N 8.113 kg/yr, P 1.123 kg/yr
10Loads out of the Wet Detentionits load in, less its series contribution expressed on the flow reaching itN 4.314 kg/yr, P 0.226 kg/yr

BMP 1: Retention

Part of the combined retention system: its Treatment Depth is added into the Equivalent Treatment Depth. Its own N and P removal below is not applied separately.

Equations

Treatment Depth (in) = Retention Volume (ac-ft) / Contributing Area (ac) x 12

Notes

Hydraulic capture efficiency is read from the retention efficiency lookup tables for the Treatment Depth.

The lookup also depends on the watershed's non-DCIA curve number, DCIA percent and rainfall zone.

N and P removal are equal to the hydraulic capture efficiency.

Values

VariableCurrent value
Retention Volume0.313 ac-ft
Contributing Area5.000 ac
Watershed Area5.000 ac
Non-DCIA Curve Number80
DCIA Percent60 %
Rainfall ZoneFlorida Zone 5
Treatment Depth0.751 in
Hydraulic Capture62.1 %
Treatment Rate(no media mix)
N removal62.1 %
P removal62.1 %

BMP 2: Wet Detention

Receives what the retention system passes on; its residence time is re-derived from that volume (see the steps above).

Equations

Residence Time rt (days) = Permanent Pool Volume (ac-ft) / Annual Runoff Volume (ac-ft) x 365

N removal (%) = 43.75 x rt / (4.38 + rt)

P removal (%) = 40.13 + 6.372 x ln(rt) + 0.213 x [ln(rt)]^2

Littoral zone: N removal = N removal + Littoral Zone Credit, P removal = P removal + Littoral Zone Credit (credit 0 to 10 %; none without one)

Wetland credit: N removal = N removal + Wetland Efficiency Credit x (100 - N removal) / 100

P removal = P removal + Wetland Efficiency Credit x (100 - P removal) / 100

Notes

Residence Time is capped at 200 days unless ART > 200 is allowed.

The littoral zone credit is added before the wetland credit (BMPFast 2: the equations are a pond without a littoral zone).

N and P removal cannot exceed 100%.

Values

VariableCurrent value
Wetland Efficiency Credit0.00 %
Permanent Pool Volume3.81 ac-ft
Annual Runoff Volume13.90 ac-ft
Treatment Rate(no media mix)
N removal53.0 %
P removal92.3 %
Effective Residence Time (routed)264.125 days
Pond N removal at that residence time43.036 %
Pond P removal at that residence time92.374 %
N series contribution17.727 %
P series contribution30.235 %