Exfiltration

Exfiltration: subdivision discharging to OFW — Exfiltration on Subdivision (stand-alone: this catchment's runoff only)
Made by BMPFast 2 on Tuesday, 20 October 2026 16:00

Exfiltration System Input Variables

Pipe Span48.00 in
Pipe Rise48.00 in
Pipe Length600.00 ft
Trench/Vault Width8.00 ft
Trench Depth6.00 ft
Trench Length600.00 ft
Void Ratio0.35 fraction
Pipe Volume7,539.82 cf
Trench/Vault Volume7,441.06 cf
Treatment Volume0.34 ac-ft
Treatment Depth0.83 in over CA
Treatment Depth0.83 in
Time to Recover Design Volume72.00 hr

Watershed Characteristics

Watershed Area5.00 acres
Contributing Area to BMP5.00 ac
Watershed Non-DCIA Curve Number (0-100)75
Watershed DCIA Percent25.00 %
Rainfall ZoneFlorida Zone 1
Rainfall62.00 in

Surface Water Discharge

Provided Nitrogen Treatment Efficiency70.8 %
Provided Phosphorus Treatment Efficiency70.8 %

Groundwater Discharge (Stand-Alone)

Average Annual Recharge0.00 MG/yr
TN Mass Load12.09 kg/yr
TN Concentration0.00 mg/L
TP Mass Load2.23 kg/yr
TP Concentration0.00 mg/L

Surface Discharge Load Diagram for Exfiltration (stand-alone)

Runoff input is only from this catchment, no routing is performed here

Load

N17.08 kg/yr
P3.16 kg/yr
Q7.83 ac-ft/yr

Treatment

N71 %
P71 %

Surface Discharge

N4.99 kg/yr
P0.92 kg/yr
Q2.29 ac-ft/yr

Mass Reduction

N12.09 kg/yr
P2.23 kg/yr
Q5.54 ac-ft/yr

Storage (v1's Exfiltration Calculator)

Exfiltration System Input Variables

Pipe Span48.00 in
Pipe Rise48.00 in
Pipe Length600.00 ft
Trench/Vault Width8.00 ft
Trench Depth6.00 ft
Trench Length600.00 ft
Void Ratio0.35 fraction
Pipe Volume7,539.82 cf
Trench/Vault Volume7,441.06 cf
Treatment Volume0.34 ac-ft
Treatment Depth0.83 in over CA
Treatment Depth0.83 in
Time to Recover Design Volume72.00 hr

Exfiltration Storage Variables

Pipe Volume7,539.82 cf
Trench/Vault Volume7,441.06 cf
Treatment Volume0.34 ac-ft
Treatment Depth0.83 in over CA

Equations

The equations behind the values above, and the values they are worked with (v1's Equations page).

Exfiltration — Equations

Equations

Pipe Volume (cf) = pi x (Pipe Span / 24) x (Pipe Rise / 24) x Pipe Length

Trench Volume (cf) = (Trench Width x Trench Depth x Trench Length - Pipe Volume) x Void Ratio

Treatment Volume (ac-ft) = (Pipe Volume + Trench Volume) / 43560

Treatment Depth (in) = Treatment Volume / Contributing Area (ac) x 12

Notes

Hydraulic capture efficiency is read from the retention efficiency lookup tables for the Treatment Depth.

The lookup also depends on the watershed's non-DCIA curve number, DCIA percent and rainfall zone.

N and P removal are equal to the hydraulic capture efficiency.

Values

VariableCurrent value
Pipe Span48.00 in
Pipe Rise48.00 in
Pipe Length600.00 ft
Trench Length600.00 ft
Trench/Vault Width8.00 ft
Trench Depth6.00 ft
Void Ratio0.35 fraction
Contributing Area5.000 ac
Watershed Area5.000 ac
Non-DCIA Curve Number75
DCIA Percent25 %
Rainfall ZoneFlorida Zone 1
Treatment Depth0.825 in
Hydraulic Capture70.8 %
Treatment Rate(no media mix)
N removal70.8 %
P removal70.8 %