How this treatment's values are worked out: the equations, then the values they are worked with (v1's Equations button). A change on the Entry or Sizing tab shows here at once.
Pipe Volume (cf) = pi x (Pipe Span / 24) x (Pipe Rise / 24) x Pipe Length
Trench Volume (cf) = (Trench Width x Trench Depth x Trench Length - Pipe Volume) x Void Ratio
Treatment Volume (ac-ft) = (Pipe Volume + Trench Volume) / 43560
Treatment Depth (in) = Treatment Volume / Contributing Area (ac) x 12
Hydraulic capture efficiency is read from the retention efficiency lookup tables for the Treatment Depth.
The lookup also depends on the watershed's non-DCIA curve number, DCIA percent and rainfall zone.
N and P removal are equal to the hydraulic capture efficiency.
| Variable | Current value |
|---|---|
| Pipe Span | 48.00 in |
| Pipe Rise | 48.00 in |
| Pipe Length | 600.00 ft |
| Trench Length | 600.00 ft |
| Trench/Vault Width | 8.00 ft |
| Trench Depth | 6.00 ft |
| Void Ratio | 0.35 fraction |
| Contributing Area | 5.000 ac |
| Watershed Area | 5.000 ac |
| Non-DCIA Curve Number | 75 |
| DCIA Percent | 25 % |
| Rainfall Zone | Florida Zone 1 |
| Treatment Depth | 0.825 in |
| Hydraulic Capture | 70.8 % |
| Treatment Rate | (no media mix) |
| N removal | 70.8 % |
| P removal | 70.8 % |