Exfiltration
Exfiltration trench: commercial site — Exfiltration on Commercial site (stand-alone: this catchment's runoff only)
Made by BMPFast 2 on Tuesday, 20 October 2026 16:00
Exfiltration System Input Variables
| Pipe Span | 36.00 in |
| Pipe Rise | 36.00 in |
| Pipe Length | 300.00 ft |
| Trench/Vault Width | 6.00 ft |
| Trench Depth | 5.00 ft |
| Trench Length | 300.00 ft |
| Void Ratio | 0.40 fraction |
| Pipe Volume | 2,120.58 cf |
| Trench/Vault Volume | 2,751.77 cf |
| Treatment Volume | 0.11 ac-ft |
| Treatment Depth | 0.67 in over CA |
| Treatment Depth | 0.67 in |
| Time to Recover Design Volume | 72.00 hr |
Watershed Characteristics
| Watershed Area | 2.00 acres |
| Contributing Area to BMP | 2.00 ac |
| Watershed Non-DCIA Curve Number (0-100) | 80 |
| Watershed DCIA Percent | 70.00 % |
| Rainfall Zone | Florida Zone 3 |
| Rainfall | 54.00 in |
Surface Water Discharge
| Provided Nitrogen Treatment Efficiency | 59.6 % |
| Provided Phosphorus Treatment Efficiency | 59.6 % |
Groundwater Discharge (Stand-Alone)
| Average Annual Recharge | 0.00 MG/yr |
| TN Mass Load | 9.46 kg/yr |
| TN Concentration | 0.00 mg/L |
| TP Mass Load | 1.36 kg/yr |
| TP Concentration | 0.00 mg/L |
Surface Discharge Load Diagram for Exfiltration (stand-alone)
Runoff input is only from this catchment, no routing is performed here
Load
| N | 15.87 kg/yr |
| P | 2.28 kg/yr |
| Q | 5.36 ac-ft/yr |
Treatment
Surface Discharge
| N | 6.41 kg/yr |
| P | 0.92 kg/yr |
| Q | 2.17 ac-ft/yr |
Mass Reduction
| N | 9.46 kg/yr |
| P | 1.36 kg/yr |
| Q | 3.20 ac-ft/yr |
Storage (v1's Exfiltration Calculator)
Exfiltration System Input Variables
| Pipe Span | 36.00 in |
| Pipe Rise | 36.00 in |
| Pipe Length | 300.00 ft |
| Trench/Vault Width | 6.00 ft |
| Trench Depth | 5.00 ft |
| Trench Length | 300.00 ft |
| Void Ratio | 0.40 fraction |
| Pipe Volume | 2,120.58 cf |
| Trench/Vault Volume | 2,751.77 cf |
| Treatment Volume | 0.11 ac-ft |
| Treatment Depth | 0.67 in over CA |
| Treatment Depth | 0.67 in |
| Time to Recover Design Volume | 72.00 hr |
Exfiltration Storage Variables
| Pipe Volume | 2,120.58 cf |
| Trench/Vault Volume | 2,751.77 cf |
| Treatment Volume | 0.11 ac-ft |
| Treatment Depth | 0.67 in over CA |
Equations
The equations behind the values above, and the values they are worked with (v1's Equations page).
Exfiltration — Equations
Equations
Pipe Volume (cf) = pi x (Pipe Span / 24) x (Pipe Rise / 24) x Pipe Length
Trench Volume (cf) = (Trench Width x Trench Depth x Trench Length - Pipe Volume) x Void Ratio
Treatment Volume (ac-ft) = (Pipe Volume + Trench Volume) / 43560
Treatment Depth (in) = Treatment Volume / Contributing Area (ac) x 12
Notes
Hydraulic capture efficiency is read from the retention efficiency lookup tables for the Treatment Depth.
The lookup also depends on the watershed's non-DCIA curve number, DCIA percent and rainfall zone.
N and P removal are equal to the hydraulic capture efficiency.
Values
| Variable | Current value |
| Pipe Span | 36.00 in |
| Pipe Rise | 36.00 in |
| Pipe Length | 300.00 ft |
| Trench Length | 300.00 ft |
| Trench/Vault Width | 6.00 ft |
| Trench Depth | 5.00 ft |
| Void Ratio | 0.40 fraction |
| Contributing Area | 2.000 ac |
| Watershed Area | 2.000 ac |
| Non-DCIA Curve Number | 80 |
| DCIA Percent | 70 % |
| Rainfall Zone | Florida Zone 3 |
| Treatment Depth | 0.671 in |
| Hydraulic Capture | 59.6 % |
| Treatment Rate | (no media mix) |
| N removal | 59.6 % |
| P removal | 59.6 % |