| Treatment Depth | 0.50 in |
| Hydraulic Capture Efficiency | 71.50 % |
| Type of Media Mix | B&G CTS12 |
| Media N Reduction | 60.00 % |
| Media P Reduction | 90.00 % |
| Watershed Area | 5.00 acres |
| Contributing Area to BMP | 5.00 ac |
| Watershed Non-DCIA Curve Number (0-100) | 75 |
| Watershed DCIA Percent | 25.00 % |
| Rainfall Zone | Florida Zone 2 |
| Rainfall | 50.00 in |
| Provided Nitrogen Treatment Efficiency | 42.9 % |
| Provided Phosphorus Treatment Efficiency | 64.3 % |
Media Mix Information
| Parameter | Value |
|---|---|
| Type of Media Mix | B&G CTS12 |
| Media N Reduction (%) | 60 |
| Media P Reduction (%) | 90 |
Note: Media Layer Depth not entered. B&G CTS12 needs at least 12 in (design guidance from the media suppliers; see the Media Mix help page). Enter the depth in Enter Media Mix Information to check it.
Filtered Water (Stand-Alone)
| Parameter | Value |
|---|---|
| Volume Filtered (MG/yr) | 1.272 |
| TN Load in the Filtered Water (kg/yr) | 3.407 |
| TN Concentration in the Filtered Water (mg/L) | 0.708 |
| TP Load in the Filtered Water (kg/yr) | 0.157 |
| TP Concentration in the Filtered Water (mg/L) | 0.033 |
The filtered water is discharged to the surface. The runoff the filter does not capture bypasses it untreated; the Surface Water Discharge table above shows the total leaving the BMP.
Runoff input is only from this catchment, no routing is performed here
| N | 11.91 kg/yr |
| P | 2.20 kg/yr |
| Q | 5.46 ac-ft/yr |
| N | 43 % |
| P | 64 % |
| N | 6.80 kg/yr |
| P | 0.78 kg/yr |
| Q | 5.46 ac-ft/yr |
| N | 5.11 kg/yr |
| P | 1.42 kg/yr |
| Q | 0.00 ac-ft/yr |
The equations behind the values above, and the values they are worked with (v1's Equations page).
Area Discharging to Filter (ac) = Contributing Area (ac) x (100 - Upstream Hydraulic Capture (%)) / 100
Treatment Depth (in) = Filter Surface Area (sf) x Rate (gpm/sf) / (18.85 x Area Discharging to Filter (ac))
18.85 = (43,560 sf/ac / 12 in/ft) / (0.0022288 cfs/gpm x 86,400 s/day): the depth of runoff, over the area discharging to the filter, that the media passes in one day
equivalently Minimum Filter Surface Area (sf) = Area Discharging to Filter (ac) x Treatment Depth (in) x 18.85 / Rate (gpm/sf)
Capture (%) = retention efficiency table lookup of Treatment Depth
Filter N removal (%) = Capture x Media N reduction / 100
Filter P removal (%) = Capture x Media P reduction / 100
Total N removal (%) = Upstream N + Filter N x (100 - Upstream N) / 100
Total P removal (%) = Upstream P + Filter P x (100 - Upstream P) / 100
Rate is the media's treatment rate in gpm/sf and includes the safety factor.
Hydraulic Capture is the water the upstream BMP retains and infiltrates. It leaves the surface-water system and never reaches the filter.
What the upstream BMP discharges is the water that overflows the pond, and that is the volume the filter has to treat. A retention-type BMP discharges (100 - Hydraulic Capture)% of the catchment runoff; a wet detention removes no volume and discharges all of it.
The filter is therefore sized against the discharged volume, expressed as the Area Discharging to Filter - the post-development catchment area scaled by what the upstream BMP passes on - not against the raw catchment area.
The area shown is the MINIMUM filter surface area for that treatment depth; a larger area is always acceptable.
The treatment efficiency assumes the built filter meets that minimum area. There is no calculation for partial treatment by an undersized filter: removal follows the Treatment Depth, not the volume reaching the filter.
The capture lookup also depends on the non-DCIA curve number, DCIA percent and rainfall zone.
With no upstream BMP (None) the catchment's runoff goes directly to the filter: its flow and N/P loading are the filter's input, Upstream Hydraulic Capture and Upstream N/P are 0, the Area Discharging to Filter is the whole catchment area, and the total removal is the filter's own.
An upstream retention BMP's removal comes from its Treatment Depth; an upstream wet detention's from its residence time.
With a wet detention upstream the media reductions for B&G ECT Mixes and SAT are reduced to 25%.
The filter acts only on the runoff the upstream BMP passes on (ordinary treatment train).
| Variable | Current value |
|---|---|
| Contributing Area | 5.000 ac |
| Watershed Area | 5.000 ac |
| Non-DCIA Curve Number | 75 |
| DCIA Percent | 25 % |
| Rainfall Zone | Florida Zone 2 |
| Treatment Depth | 0.500 in |
| Hydraulic Capture | 71.5 % |
| Treatment Rate | 0.052 gpm/sf |
| N removal | 42.9 % |
| P removal | 64.4 % |