Surface Discharge Filter

Surface discharge filter: B_G CTS24, impaired water — Surface Discharge Filter on Commercial site (stand-alone: this catchment's runoff only)
Made by BMPFast 2 on Tuesday, 20 October 2026 16:00

Filtration Input Variables

Treatment Depth1.00 in
Hydraulic Capture Efficiency71.10 %
Type of Media MixB&G CTS24
Media N Reduction75.00 %
Media P Reduction95.00 %

Watershed Characteristics

Watershed Area3.00 acres
Contributing Area to BMP3.00 ac
Watershed Non-DCIA Curve Number (0-100)80
Watershed DCIA Percent70.00 %
Rainfall ZoneFlorida Zone 3
Rainfall54.00 in

Surface Water Discharge

Provided Nitrogen Treatment Efficiency53.3 %
Provided Phosphorus Treatment Efficiency67.5 %

Media Mix Information

ParameterValue
Type of Media MixB&G CTS24
Media N Reduction (%)75
Media P Reduction (%)95

Note: Media Layer Depth not entered. B&G CTS24 needs at least 24 in (design guidance from the media suppliers; see the Media Mix help page). Enter the depth in Enter Media Mix Information to check it.

Filtered Water (Stand-Alone)

ParameterValue
Volume Filtered (MG/yr)1.864
TN Load in the Filtered Water (kg/yr)4.232
TN Concentration in the Filtered Water (mg/L)0.600
TP Load in the Filtered Water (kg/yr)0.122
TP Concentration in the Filtered Water (mg/L)0.017

The filtered water is discharged to the surface. The runoff the filter does not capture bypasses it untreated; the Surface Water Discharge table above shows the total leaving the BMP.

Surface Discharge Load Diagram for Surface Discharge Filtration (stand-alone)

Runoff input is only from this catchment, no routing is performed here

Load

N23.81 kg/yr
P3.42 kg/yr
Q8.05 ac-ft/yr

Treatment

N53 %
P68 %

Surface Discharge

N11.11 kg/yr
P1.11 kg/yr
Q8.05 ac-ft/yr

Mass Reduction

N12.70 kg/yr
P2.31 kg/yr
Q0.00 ac-ft/yr

Equations

The equations behind the values above, and the values they are worked with (v1's Equations page).

Surface Discharge Filtration — Equations

Equations

Area Discharging to Filter (ac) = Contributing Area (ac) x (100 - Upstream Hydraulic Capture (%)) / 100

Treatment Depth (in) = Filter Surface Area (sf) x Rate (gpm/sf) / (18.85 x Area Discharging to Filter (ac))

18.85 = (43,560 sf/ac / 12 in/ft) / (0.0022288 cfs/gpm x 86,400 s/day): the depth of runoff, over the area discharging to the filter, that the media passes in one day

equivalently Minimum Filter Surface Area (sf) = Area Discharging to Filter (ac) x Treatment Depth (in) x 18.85 / Rate (gpm/sf)

Capture (%) = retention efficiency table lookup of Treatment Depth

Filter N removal (%) = Capture x Media N reduction / 100

Filter P removal (%) = Capture x Media P reduction / 100

Total N removal (%) = Upstream N + Filter N x (100 - Upstream N) / 100

Total P removal (%) = Upstream P + Filter P x (100 - Upstream P) / 100

Notes

Rate is the media's treatment rate in gpm/sf and includes the safety factor.

Hydraulic Capture is the water the upstream BMP retains and infiltrates. It leaves the surface-water system and never reaches the filter.

What the upstream BMP discharges is the water that overflows the pond, and that is the volume the filter has to treat. A retention-type BMP discharges (100 - Hydraulic Capture)% of the catchment runoff; a wet detention removes no volume and discharges all of it.

The filter is therefore sized against the discharged volume, expressed as the Area Discharging to Filter - the post-development catchment area scaled by what the upstream BMP passes on - not against the raw catchment area.

The area shown is the MINIMUM filter surface area for that treatment depth; a larger area is always acceptable.

The treatment efficiency assumes the built filter meets that minimum area. There is no calculation for partial treatment by an undersized filter: removal follows the Treatment Depth, not the volume reaching the filter.

The capture lookup also depends on the non-DCIA curve number, DCIA percent and rainfall zone.

With no upstream BMP (None) the catchment's runoff goes directly to the filter: its flow and N/P loading are the filter's input, Upstream Hydraulic Capture and Upstream N/P are 0, the Area Discharging to Filter is the whole catchment area, and the total removal is the filter's own.

An upstream retention BMP's removal comes from its Treatment Depth; an upstream wet detention's from its residence time.

With a wet detention upstream the media reductions for B&G ECT Mixes and SAT are reduced to 25%.

The filter acts only on the runoff the upstream BMP passes on (ordinary treatment train).

Values

VariableCurrent value
Contributing Area3.000 ac
Watershed Area3.000 ac
Non-DCIA Curve Number80
DCIA Percent70 %
Rainfall ZoneFlorida Zone 3
Treatment Depth1.000 in
Hydraulic Capture71.1 %
Treatment Rate0.052 gpm/sf
N removal53.3 %
P removal67.5 %