Surface Discharge Filter Sizing — calculations

Ex # 5 ret to det one catch
Made by BMPFast 2 on Tuesday, 20 October 2026 16:00

How the calculator's results are worked out: the equations, then the values they are worked with (v1's Equations button). A change on the Entry tab shows here at once.

Equations

Equation
Area Discharging to Filter (ac) = Contributing Area (ac) x (100 - Upstream Hydraulic Capture (%)) / 100
Treatment Depth (in) = Filter Surface Area (sf) x Rate (gpm/sf) / (18.85 x Area Discharging to Filter (ac))
18.85 = (43,560 sf/ac / 12 in/ft) / (0.0022288 cfs/gpm x 86,400 s/day): the depth of runoff, over the area discharging to the filter, that the media passes in one day
equivalently Minimum Filter Surface Area (sf) = Area Discharging to Filter (ac) x Treatment Depth (in) x 18.85 / Rate (gpm/sf)
Capture (%) = retention efficiency table lookup of Treatment Depth
Filter N removal (%) = Capture x Media N reduction / 100
Filter P removal (%) = Capture x Media P reduction / 100
Total N removal (%) = Upstream N + Filter N x (100 - Upstream N) / 100
Total P removal (%) = Upstream P + Filter P x (100 - Upstream P) / 100

Notes

Note
Rate is the media's treatment rate in gpm/sf and includes the safety factor.
Hydraulic Capture is the water the upstream BMP retains and infiltrates. It leaves the surface-water system and never reaches the filter.
What the upstream BMP discharges is the water that overflows the pond, and that is the volume the filter has to treat. A retention-type BMP discharges (100 - Hydraulic Capture)% of the catchment runoff; a wet detention removes no volume and discharges all of it.
The filter is therefore sized against the discharged volume, expressed as the Area Discharging to Filter - the post-development catchment area scaled by what the upstream BMP passes on - not against the raw catchment area.
The area shown is the MINIMUM filter surface area for that treatment depth; a larger area is always acceptable.
The treatment efficiency assumes the built filter meets that minimum area. There is no calculation for partial treatment by an undersized filter: removal follows the Treatment Depth, not the volume reaching the filter.
The capture lookup also depends on the non-DCIA curve number, DCIA percent and rainfall zone.
With no upstream BMP (None) the catchment's runoff goes directly to the filter: its flow and N/P loading are the filter's input, Upstream Hydraulic Capture and Upstream N/P are 0, the Area Discharging to Filter is the whole catchment area, and the total removal is the filter's own.
An upstream retention BMP's removal comes from its Treatment Depth; an upstream wet detention's from its residence time.
With a wet detention upstream the media reductions for B&G ECT Mixes and SAT are reduced to 25%.
The filter acts only on the runoff the upstream BMP passes on (ordinary treatment train).

Upstream treatment, Wet Detention: Residence Time rt (days) = Permanent Pool Volume (ac-ft) / Annual Runoff Volume (ac-ft) x 365 N removal (%) = 43.75 x rt / (4.38 + rt) P removal (%) = 40.13 + 6.372 x ln(rt) + 0.213 x [ln(rt)]^2 Littoral zone: N removal = N removal + Littoral Zone Credit, P removal = P removal + Littoral Zone Credit (credit 0 to 10 %; none without one) Wetland credit: N removal = N removal + Wetland Efficiency Credit x (100 - N removal) / 100 P removal = P removal + Wetland Efficiency Credit x (100 - P removal) / 100 Residence Time is capped at 200 days unless ART > 200 is allowed. The littoral zone credit is added before the wetland credit (BMPFast 2: the equations are a pond without a littoral zone). N and P removal cannot exceed 100%.