Surface Discharge Filter Sizing

Example Problem # 3
Made by BMPFast 2 on Tuesday, 20 October 2026 16:00

Filter and what feeds it

Catchmentcatchment 1
Surface Discharge FilterSurface Discharge Filter
Upstream treatmentRetention
UpstreamRemoves nitrogen 75.0 %, phosphorus 75.0 %; captures 75.0 %, so 2.749 of 11.000 ac drains to the filter.
Filter mediaB&G CTS12
Treatment rate0.052 gpm/sf

Targets

Nitrogen removal to meet85.0 %
Phosphorus removal to meet90.0 %

Filter surface area

Filter surface area410 sf
Area chosen byBMPFast: where both targets are first met
Treatment depth0.411 in

Results

Filter (media) removalnitrogen 40.1 %, phosphorus 60.1 %
Total removal (upstream + filter)nitrogen 85.0 %, phosphorus 90.0 % — meets both targets
Where both targets are met410 sf (treatment depth 0.411 in)

Chart range

Chart areas from 0 to1,000 sf

Equations

Equation
Area Discharging to Filter (ac) = Contributing Area (ac) x (100 - Upstream Hydraulic Capture (%)) / 100
Treatment Depth (in) = Filter Surface Area (sf) x Rate (gpm/sf) / (18.85 x Area Discharging to Filter (ac))
18.85 = (43,560 sf/ac / 12 in/ft) / (0.0022288 cfs/gpm x 86,400 s/day): the depth of runoff, over the area discharging to the filter, that the media passes in one day
equivalently Minimum Filter Surface Area (sf) = Area Discharging to Filter (ac) x Treatment Depth (in) x 18.85 / Rate (gpm/sf)
Capture (%) = retention efficiency table lookup of Treatment Depth
Filter N removal (%) = Capture x Media N reduction / 100
Filter P removal (%) = Capture x Media P reduction / 100
Total N removal (%) = Upstream N + Filter N x (100 - Upstream N) / 100
Total P removal (%) = Upstream P + Filter P x (100 - Upstream P) / 100

Notes

Note
Rate is the media's treatment rate in gpm/sf and includes the safety factor.
Hydraulic Capture is the water the upstream BMP retains and infiltrates. It leaves the surface-water system and never reaches the filter.
What the upstream BMP discharges is the water that overflows the pond, and that is the volume the filter has to treat. A retention-type BMP discharges (100 - Hydraulic Capture)% of the catchment runoff; a wet detention removes no volume and discharges all of it.
The filter is therefore sized against the discharged volume, expressed as the Area Discharging to Filter - the post-development catchment area scaled by what the upstream BMP passes on - not against the raw catchment area.
The area shown is the MINIMUM filter surface area for that treatment depth; a larger area is always acceptable.
The treatment efficiency assumes the built filter meets that minimum area. There is no calculation for partial treatment by an undersized filter: removal follows the Treatment Depth, not the volume reaching the filter.
The capture lookup also depends on the non-DCIA curve number, DCIA percent and rainfall zone.
With no upstream BMP (None) the catchment's runoff goes directly to the filter: its flow and N/P loading are the filter's input, Upstream Hydraulic Capture and Upstream N/P are 0, the Area Discharging to Filter is the whole catchment area, and the total removal is the filter's own.
An upstream retention BMP's removal comes from its Treatment Depth; an upstream wet detention's from its residence time.
With a wet detention upstream the media reductions for B&G ECT Mixes and SAT are reduced to 25%.
The filter acts only on the runoff the upstream BMP passes on (ordinary treatment train).

Upstream treatment, Retention: Treatment Depth (in) = Retention Volume (ac-ft) / Contributing Area (ac) x 12 Hydraulic capture efficiency is read from the retention efficiency lookup tables for the Treatment Depth. The lookup also depends on the watershed's non-DCIA curve number, DCIA percent and rainfall zone. N and P removal are equal to the hydraulic capture efficiency.