| Equation |
| Area Discharging to Filter (ac) = Contributing Area (ac) x (100 - Upstream Hydraulic Capture (%)) / 100 |
| Treatment Depth (in) = Filter Surface Area (sf) x Rate (gpm/sf) / (18.85 x Area Discharging to Filter (ac)) |
| 18.85 = (43,560 sf/ac / 12 in/ft) / (0.0022288 cfs/gpm x 86,400 s/day): the depth of runoff, over the area discharging to the filter, that the media passes in one day |
| equivalently Minimum Filter Surface Area (sf) = Area Discharging to Filter (ac) x Treatment Depth (in) x 18.85 / Rate (gpm/sf) |
| Capture (%) = retention efficiency table lookup of Treatment Depth |
| Filter N removal (%) = Capture x Media N reduction / 100 |
| Filter P removal (%) = Capture x Media P reduction / 100 |
| Total N removal (%) = Upstream N + Filter N x (100 - Upstream N) / 100 |
| Total P removal (%) = Upstream P + Filter P x (100 - Upstream P) / 100 |
| Note |
| Rate is the media's treatment rate in gpm/sf and includes the safety factor. |
| Hydraulic Capture is the water the upstream BMP retains and infiltrates. It leaves the surface-water system and never reaches the filter. |
| What the upstream BMP discharges is the water that overflows the pond, and that is the volume the filter has to treat. A retention-type BMP discharges (100 - Hydraulic Capture)% of the catchment runoff; a wet detention removes no volume and discharges all of it. |
| The filter is therefore sized against the discharged volume, expressed as the Area Discharging to Filter - the post-development catchment area scaled by what the upstream BMP passes on - not against the raw catchment area. |
| The area shown is the MINIMUM filter surface area for that treatment depth; a larger area is always acceptable. |
| The treatment efficiency assumes the built filter meets that minimum area. There is no calculation for partial treatment by an undersized filter: removal follows the Treatment Depth, not the volume reaching the filter. |
| The capture lookup also depends on the non-DCIA curve number, DCIA percent and rainfall zone. |
| With no upstream BMP (None) the catchment's runoff goes directly to the filter: its flow and N/P loading are the filter's input, Upstream Hydraulic Capture and Upstream N/P are 0, the Area Discharging to Filter is the whole catchment area, and the total removal is the filter's own. |
| An upstream retention BMP's removal comes from its Treatment Depth; an upstream wet detention's from its residence time. |
| With a wet detention upstream the media reductions for B&G ECT Mixes and SAT are reduced to 25%. |
| The filter acts only on the runoff the upstream BMP passes on (ordinary treatment train). |
Upstream treatment, Retention: Treatment Depth (in) = Retention Volume (ac-ft) / Contributing Area (ac) x 12 Hydraulic capture efficiency is read from the retention efficiency lookup tables for the Treatment Depth. The lookup also depends on the watershed's non-DCIA curve number, DCIA percent and rainfall zone. N and P removal are equal to the hydraulic capture efficiency.