Routing 1

Vegetated filter strip: detention with media — Catchment Routing results
Made by BMPFast 2 on Tuesday, 20 October 2026 16:00

Calculated with v1's engine, by Strand routing (v1's routing; use this for permits), so an opened v1 project gives the numbers v1 gives. This is the summary; v1's reports for this routing (Summary, Complete, Flow Balance, Full Routing Diagram, compliance, catchments and their treatments) are in the Report list above.

Nitrogen

Total Outlet Nitrogen Loading1.55 kg/yr
Total Catchment Nitrogen Loading6.36 kg/yr
Provided Nitrogen Treatment Efficiency75.60 %

Phosphorus

Total Outlet Phosphorus Loading0.06 kg/yr
Total Catchment Phosphorus Loading0.88 kg/yr
Provided Phosphorus Treatment Efficiency92.70 %

Runoff and area

Pre-development runoff volume0.61 ac-ft/yr
Post-development runoff volume leaving the site4.12 ac-ft/yr
Pre-Condition Catchment Area2.00 ac
Post Condition Catchment Area2.00 ac

Requirement

Type of analysisImpaired Water + OFW
Nitrogen Removal Performance Specified (by the type of analysis)95.00 %
Phosphorus Removal Performance Specified (by the type of analysis)95.00 %
Nitrogen removal for post = pre87.0 %
Phosphorus removal for post = pre96.3 %
Nitrogen removal to meet (the greater)95.0 %
Phosphorus removal to meet (the greater)96.3 %

Meets the required removal? Nitrogen: no (75.60 % provided, 95.0 % needed). Phosphorus: no (92.70 % provided, 96.3 % needed). The removal needed is the greater of the type of analysis's percentage and the post = pre removal, as in v1's reports.

How each catchment is routed

CatchmentDrains toTreatment usedLeft out
HighwayOutletVegetated Filter Strip