| System Type | Retention |
| VFS Width | 20.00 ft |
| VFS Length | 400.00 ft |
| VFS Depth | 1.00 ft |
| Width of Area Feeding VFS | 109.00 ft |
| Water storage capacity of soil | 0.20 in/in |
| Slope of VFS | 2.00 % |
| Runoff Area (Width of Area Feeding VFS x Length) | 1.001 acres |
| VFS Area (Width x Length) | 0.184 acres |
| Contributing Area (Runoff Area + VFS Area) | 1.185 acres |
| Watershed Area | 1.00 acres |
| Treatment Volume | 0.037 ac-ft |
| Treatment Depth | 0.37 in |
Warning: the Contributing Area (Runoff Area + VFS Area) is 1.185 acres, but the catchment's area (Watershed Area, from 1. Enter Catchment) is 1.000 acres. They must be equal (within 1 %): the catchment is the area that drains to the VFS plus the VFS itself. The loads come from the catchment's area; the treatment is calculated from these dimensions. With this length and width, a Width of Area Feeding VFS of 88.9 ft matches it; that also changes the Treatment Depth and so the removal, so Calculate again and check them.
| Watershed Area | 1.00 acres |
| Contributing Area to BMP | 1.18 ac |
| Watershed Non-DCIA Curve Number (0-100) | 80 |
| Watershed DCIA Percent | 60.00 % |
| Rainfall Zone | Florida Zone 2 |
| Rainfall | 50.00 in |
| Provided Nitrogen Treatment Efficiency | 46.5 % |
| Provided Phosphorus Treatment Efficiency | 46.5 % |
| Average Annual Recharge | 0.00 MG/yr |
| TN Mass Load | 1.18 kg/yr |
| TN Concentration | 0.00 mg/L |
| TP Mass Load | 0.24 kg/yr |
| TP Concentration | 0.00 mg/L |
Runoff input is only from this catchment, no routing is performed here
| N | 2.53 kg/yr |
| P | 0.52 kg/yr |
| Q | 2.21 ac-ft/yr |
| N | 47 % |
| P | 47 % |
| N | 1.35 kg/yr |
| P | 0.28 kg/yr |
| Q | 1.18 ac-ft/yr |
| N | 1.18 kg/yr |
| P | 0.24 kg/yr |
| Q | 1.03 ac-ft/yr |
The equations behind the values above, and the values they are worked with (v1's Equations page).
Treatment Volume (ac-ft) = VFS Width x VFS Length x VFS Depth x Soil Storage Capacity / 43560
Treatment Depth (in) = 12 in/ft x VFS Width x VFS Depth x Soil Storage Capacity / (VFS Width + Width of Area Feeding VFS)
Hydraulic Capture (%) = retention curves (Treatment Depth, non-DCIA CN, DCIA %, rainfall zone)
N removal (%) = P removal (%) = Hydraulic Capture
Retention: Hydraulic capture efficiency is read from the retention efficiency lookup tables for the Treatment Depth.
The lookup also depends on the watershed's non-DCIA curve number, DCIA percent and rainfall zone.
The buffer tables and the media mix do not change the removal; in Retention a media mix is used in the groundwater analysis.
| Variable | Current value |
|---|---|
| VFS Width | 20.00 ft |
| VFS Length | 400.00 ft |
| VFS Depth | 1.00 ft |
| Width of Area Feeding VFS | 109.00 ft |
| Slope of VFS | 2.00 % |
| Water storage capacity of soil | 0.20 in/in |
| Contributing Area | 1.185 ac |
| Watershed Area | 1.000 ac |
| Non-DCIA Curve Number | 80 |
| DCIA Percent | 60 % |
| Rainfall Zone | Florida Zone 2 |
| Treatment Depth | 0.372 in |
| Hydraulic Capture | 46.5 % |
| Treatment Rate | (no media mix) |
| N removal | 46.5 % |
| P removal | 46.5 % |