Greenroof

Greenroof: with cistern for irrigation — Greenroof on Hotel roof (stand-alone: this catchment's runoff only)
Made by BMPFast 2 on Tuesday, 20 October 2026 16:00

Greenroof Input Variables

Selected Rainfall StationMiami #5663
Greenroof Area43,560.00 sf
Treatment Depth2.00 in
Irrigation Demand20.00 inches/year
Rainfall Excess (filtrate underdrain flow)0.00 in/yr

Removal method: the rainfall station curves (Hardin 2006): removal = max(c, a ln(cistern storage) + b).

Water Budget

Irrigation Water Use543,086 gal/yr
Harvested Water Supply0 gal/yr
Supplemental Water Needed543,086 gal/yr

The cistern's water budget: the filtrate it collects irrigates the roof. Supplemental Water Needed = Irrigation Water Use - Harvested Water Supply (0 when the supply covers the use). Rainfall Excess was not entered, so no harvested supply is counted and all of the irrigation is supplemental.

Watershed Characteristics

Watershed Area1.00 acres
Contributing Area to BMP1.00 ac
Watershed Non-DCIA Curve Number (0-100)98
Watershed DCIA Percent100.00 %
Rainfall ZoneFlorida Zone 5
Rainfall60.00 in

Surface Water Discharge

Provided Nitrogen Treatment Efficiency69.1 %
Provided Phosphorus Treatment Efficiency69.1 %

Groundwater Discharge (Stand-Alone)

Average Annual Recharge0.00 MG/yr
TN Mass Load0.00 kg/yr
TN Concentration0.00 mg/L
TP Mass Load0.00 kg/yr
TP Concentration0.00 mg/L

Surface Discharge Load Diagram for Greenroof (stand-alone)

Runoff input is only from this catchment, no routing is performed here

Load

N5.23 kg/yr
P0.60 kg/yr
Q4.04 ac-ft/yr

Treatment

N69 %
P69 %

Surface Discharge

N1.62 kg/yr
P0.18 kg/yr
Q1.25 ac-ft/yr

Mass Reduction

N3.61 kg/yr
P0.41 kg/yr
Q2.79 ac-ft/yr

Equations

The equations behind the values above, and the values they are worked with (v1's Equations page).

Greenroof — Equations

Equations

Treatment Depth (in) = Cistern Storage (in over Greenroof Area)

No cistern (storage 0): Removal Efficiency (%) = c

With a cistern: Removal Efficiency (%) = max(c, a x ln(Cistern Storage) + b)

Irrigation Water Use (gal/yr) = Irrigation Demand (in/yr) / 12 x Greenroof Area (sf) x 7.48052 gal/cf

Harvested Water Supply (gal/yr) = Removal Efficiency / 100 x Rainfall Excess (in/yr) / 12 x Greenroof Area (sf) x 7.48052 gal/cf (0 with no cistern)

Supplemental Water Needed (gal/yr) = Irrigation Water Use - Harvested Water Supply (0 when the supply covers the use)

Notes

Cistern Storage is entered directly; there is no depth derivation.

a, b and c are the coefficients of the selected Rainfall Station; c is its removal with no cistern.

A cistern never gives less removal than no cistern: below about 0.11-0.16 in the curve a x ln(storage) + b is lower than c, and c is used.

N and P removal are equal.

The water budget is calculated only when Irrigation Demand or Rainfall Excess is entered; it does not change the removal.

Values

VariableCurrent value
Greenroof Storage2.00 in over Greenroof Area
Contributing Area1.000 ac
Watershed Area1.000 ac
Non-DCIA Curve Number98
DCIA Percent100 %
Rainfall ZoneFlorida Zone 5
Treatment Depth2.000 in
Hydraulic Capture69.0 %
Treatment Rate(no media mix)
N removal69.1 %
P removal69.1 %