| Selected Rainfall Station | Miami #5663 |
| Greenroof Area | 43,560.00 sf |
| Treatment Depth | 2.00 in |
| Irrigation Demand | 20.00 inches/year |
| Rainfall Excess (filtrate underdrain flow) | 0.00 in/yr |
Removal method: the rainfall station curves (Hardin 2006): removal = max(c, a ln(cistern storage) + b).
| Irrigation Water Use | 543,086 gal/yr |
| Harvested Water Supply | 0 gal/yr |
| Supplemental Water Needed | 543,086 gal/yr |
The cistern's water budget: the filtrate it collects irrigates the roof. Supplemental Water Needed = Irrigation Water Use - Harvested Water Supply (0 when the supply covers the use). Rainfall Excess was not entered, so no harvested supply is counted and all of the irrigation is supplemental.
| Watershed Area | 1.00 acres |
| Contributing Area to BMP | 1.00 ac |
| Watershed Non-DCIA Curve Number (0-100) | 98 |
| Watershed DCIA Percent | 100.00 % |
| Rainfall Zone | Florida Zone 5 |
| Rainfall | 60.00 in |
| Provided Nitrogen Treatment Efficiency | 69.1 % |
| Provided Phosphorus Treatment Efficiency | 69.1 % |
| Average Annual Recharge | 0.00 MG/yr |
| TN Mass Load | 0.00 kg/yr |
| TN Concentration | 0.00 mg/L |
| TP Mass Load | 0.00 kg/yr |
| TP Concentration | 0.00 mg/L |
Runoff input is only from this catchment, no routing is performed here
| N | 5.23 kg/yr |
| P | 0.60 kg/yr |
| Q | 4.04 ac-ft/yr |
| N | 69 % |
| P | 69 % |
| N | 1.62 kg/yr |
| P | 0.18 kg/yr |
| Q | 1.25 ac-ft/yr |
| N | 3.61 kg/yr |
| P | 0.41 kg/yr |
| Q | 2.79 ac-ft/yr |
The equations behind the values above, and the values they are worked with (v1's Equations page).
Treatment Depth (in) = Cistern Storage (in over Greenroof Area)
No cistern (storage 0): Removal Efficiency (%) = c
With a cistern: Removal Efficiency (%) = max(c, a x ln(Cistern Storage) + b)
Irrigation Water Use (gal/yr) = Irrigation Demand (in/yr) / 12 x Greenroof Area (sf) x 7.48052 gal/cf
Harvested Water Supply (gal/yr) = Removal Efficiency / 100 x Rainfall Excess (in/yr) / 12 x Greenroof Area (sf) x 7.48052 gal/cf (0 with no cistern)
Supplemental Water Needed (gal/yr) = Irrigation Water Use - Harvested Water Supply (0 when the supply covers the use)
Cistern Storage is entered directly; there is no depth derivation.
a, b and c are the coefficients of the selected Rainfall Station; c is its removal with no cistern.
A cistern never gives less removal than no cistern: below about 0.11-0.16 in the curve a x ln(storage) + b is lower than c, and c is used.
N and P removal are equal.
The water budget is calculated only when Irrigation Demand or Rainfall Excess is entered; it does not change the removal.
| Variable | Current value |
|---|---|
| Greenroof Storage | 2.00 in over Greenroof Area |
| Contributing Area | 1.000 ac |
| Watershed Area | 1.000 ac |
| Non-DCIA Curve Number | 98 |
| DCIA Percent | 100 % |
| Rainfall Zone | Florida Zone 5 |
| Treatment Depth | 2.000 in |
| Hydraulic Capture | 69.0 % |
| Treatment Rate | (no media mix) |
| N removal | 69.1 % |
| P removal | 69.1 % |