Routing 1

Greenroof: with cistern for irrigation — Catchment Routing results
Made by BMPFast 2 on Tuesday, 20 October 2026 16:00

Calculated with v1's engine, by Strand routing (v1's routing; use this for permits), so an opened v1 project gives the numbers v1 gives. This is the summary; v1's reports for this routing (Summary, Complete, Flow Balance, Full Routing Diagram, compliance, catchments and their treatments) are in the Report list above.

Nitrogen

Total Outlet Nitrogen Loading1.62 kg/yr
Total Catchment Nitrogen Loading5.23 kg/yr
Provided Nitrogen Treatment Efficiency69.10 %

Phosphorus

Total Outlet Phosphorus Loading0.18 kg/yr
Total Catchment Phosphorus Loading0.60 kg/yr
Provided Phosphorus Treatment Efficiency69.10 %

Runoff and area

Pre-development runoff volume0.47 ac-ft/yr
Post-development runoff volume leaving the site1.25 ac-ft/yr
Pre-Condition Catchment Area1.00 ac
Post Condition Catchment Area1.00 ac

Requirement

Type of analysisRedevelopment + Impaired
Nitrogen Removal Performance Specified (by the type of analysis)45.00 %
Phosphorus Removal Performance Specified (by the type of analysis)80.00 %
Nitrogen removal for post = pre88.1 %
Phosphorus removal for post = pre95.9 %
Nitrogen removal to meet (the greater)88.1 %
Phosphorus removal to meet (the greater)95.9 %

Meets the required removal? Nitrogen: no (69.10 % provided, 88.1 % needed). Phosphorus: no (69.10 % provided, 95.9 % needed). The removal needed is the greater of the type of analysis's percentage and the post = pre removal, as in v1's reports.

How each catchment is routed

CatchmentDrains toTreatment usedLeft out
Hotel roofOutletGreenroof