Greenroof — calculations

Greenroof: office roof, no cistern — Greenroof on Office roof (stand-alone: this catchment's runoff only)
Made by BMPFast 2 on Tuesday, 20 October 2026 16:00

How this treatment's values are worked out: the equations, then the values they are worked with (v1's Equations button). A change on the Entry or Sizing tab shows here at once.

Equations

Treatment Depth (in) = Cistern Storage (in over Greenroof Area)

No cistern (storage 0): Removal Efficiency (%) = c

With a cistern: Removal Efficiency (%) = max(c, a x ln(Cistern Storage) + b)

Irrigation Water Use (gal/yr) = Irrigation Demand (in/yr) / 12 x Greenroof Area (sf) x 7.48052 gal/cf

Harvested Water Supply (gal/yr) = Removal Efficiency / 100 x Rainfall Excess (in/yr) / 12 x Greenroof Area (sf) x 7.48052 gal/cf (0 with no cistern)

Supplemental Water Needed (gal/yr) = Irrigation Water Use - Harvested Water Supply (0 when the supply covers the use)

Notes

Cistern Storage is entered directly; there is no depth derivation.

a, b and c are the coefficients of the selected Rainfall Station; c is its removal with no cistern.

A cistern never gives less removal than no cistern: below about 0.11-0.16 in the curve a x ln(storage) + b is lower than c, and c is used.

N and P removal are equal.

The water budget is calculated only when Irrigation Demand or Rainfall Excess is entered; it does not change the removal.

Values

VariableCurrent value
Greenroof Storage0.00 in over Greenroof Area
Contributing Area0.500 ac
Watershed Area0.500 ac
Non-DCIA Curve Number98
DCIA Percent100 %
Rainfall ZoneFlorida Zone 2
Treatment Depth0.000 in
Hydraulic Capture43.0 %
Treatment Rate(no media mix)
N removal43.0 %
P removal43.0 %