Retention

Retention efficiency lookup: Zone 2 — Retention on Subdivision (stand-alone: this catchment's runoff only)
Made by BMPFast 2 on Tuesday, 20 October 2026 16:00

Retention Input Variables

Treatment Depth1.20 in
Retention Volume1.000 ac-ft
Time to Recover Design Volume72.00 hr

Watershed Characteristics

Watershed Area10.00 acres
Contributing Area to BMP10.00 ac
Watershed Non-DCIA Curve Number (0-100)75
Watershed DCIA Percent25.00 %
Rainfall ZoneFlorida Zone 2
Rainfall50.00 in

Surface Water Discharge

Provided Nitrogen Treatment Efficiency88.4 %
Provided Phosphorus Treatment Efficiency88.4 %

Groundwater Discharge (Stand-Alone)

Average Annual Recharge0.00 MG/yr
TN Mass Load21.06 kg/yr
TN Concentration0.00 mg/L
TP Mass Load3.89 kg/yr
TP Concentration0.00 mg/L

Surface Discharge Load Diagram for Retention (stand-alone)

Runoff input is only from this catchment, no routing is performed here

Load

N23.82 kg/yr
P4.40 kg/yr
Q10.92 ac-ft/yr

Treatment

N88 %
P88 %

Surface Discharge

N2.76 kg/yr
P0.51 kg/yr
Q1.27 ac-ft/yr

Mass Reduction

N21.06 kg/yr
P3.89 kg/yr
Q9.65 ac-ft/yr

Equations

The equations behind the values above, and the values they are worked with (v1's Equations page).

Retention — Equations

Equations

Treatment Depth (in) = Retention Volume (ac-ft) / Contributing Area (ac) x 12

Notes

Hydraulic capture efficiency is read from the retention efficiency lookup tables for the Treatment Depth.

The lookup also depends on the watershed's non-DCIA curve number, DCIA percent and rainfall zone.

N and P removal are equal to the hydraulic capture efficiency.

Values

VariableCurrent value
Retention Volume1.000 ac-ft
Contributing Area10.000 ac
Watershed Area10.000 ac
Non-DCIA Curve Number75
DCIA Percent25 %
Rainfall ZoneFlorida Zone 2
Treatment Depth1.200 in
Hydraulic Capture88.4 %
Treatment Rate(no media mix)
N removal88.4 %
P removal88.4 %