Retention

Retention efficiency lookup: Zone 4, between tables — Retention on Commercial site (stand-alone: this catchment's runoff only)
Made by BMPFast 2 on Tuesday, 20 October 2026 16:00

Retention Input Variables

Treatment Depth0.80 in
Retention Volume0.333 ac-ft
Time to Recover Design Volume72.00 hr

Watershed Characteristics

Watershed Area5.00 acres
Contributing Area to BMP5.00 ac
Watershed Non-DCIA Curve Number (0-100)80
Watershed DCIA Percent70.00 %
Rainfall ZoneFlorida Zone 4
Rainfall52.00 in

Surface Water Discharge

Provided Nitrogen Treatment Efficiency65.7 %
Provided Phosphorus Treatment Efficiency65.7 %

Groundwater Discharge (Stand-Alone)

Average Annual Recharge0.00 MG/yr
TN Mass Load25.89 kg/yr
TN Concentration0.00 mg/L
TP Mass Load3.72 kg/yr
TP Concentration0.00 mg/L

Surface Discharge Load Diagram for Retention (stand-alone)

Runoff input is only from this catchment, no routing is performed here

Load

N39.43 kg/yr
P5.67 kg/yr
Q13.33 ac-ft/yr

Treatment

N66 %
P66 %

Surface Discharge

N13.54 kg/yr
P1.95 kg/yr
Q4.58 ac-ft/yr

Mass Reduction

N25.89 kg/yr
P3.72 kg/yr
Q8.75 ac-ft/yr

Equations

The equations behind the values above, and the values they are worked with (v1's Equations page).

Retention — Equations

Equations

Treatment Depth (in) = Retention Volume (ac-ft) / Contributing Area (ac) x 12

Notes

Hydraulic capture efficiency is read from the retention efficiency lookup tables for the Treatment Depth.

The lookup also depends on the watershed's non-DCIA curve number, DCIA percent and rainfall zone.

N and P removal are equal to the hydraulic capture efficiency.

Values

VariableCurrent value
Retention Volume0.333 ac-ft
Contributing Area5.000 ac
Watershed Area5.000 ac
Non-DCIA Curve Number80
DCIA Percent70 %
Rainfall ZoneFlorida Zone 4
Treatment Depth0.799 in
Hydraulic Capture65.7 %
Treatment Rate(no media mix)
N removal65.7 %
P removal65.7 %