| Pavement Surface Area | 0.50 acres |
| Total Storage of Pavement | 0.17 ac-ft |
| Watershed Area | 2.00 acres |
| Treatment Depth | 1.00 in |
| Time to Recover Design Volume | 72.00 hr |
Treatment Depth (in) = Total Storage of Pavement (ac-ft) / Watershed Area (ac) x 12. The whole catchment area is used, pavement included. Permeable pavement is always calculated as a retention BMP.
| Pavement Type | Sustainable Void (%) | Thickness (in) | Storage (in over pavement) | Storage (ac-ft) |
| Concrete Permeable Pavement | 25.00 | 6.00 | 1.500 | 0.062 |
| #57 rock(non-calcareous) | 21.00 | 12.00 | 2.520 | 0.105 |
| Total | 4.020 | 0.167 |
| Watershed Area | 2.00 acres |
| Contributing Area to BMP | 1.50 ac |
| Watershed Non-DCIA Curve Number (0-100) | 80 |
| Watershed DCIA Percent | 70.00 % |
| Rainfall Zone | Florida Zone 3 |
| Rainfall | 54.00 in |
| Provided Nitrogen Treatment Efficiency | 71.2 % |
| Provided Phosphorus Treatment Efficiency | 71.2 % |
| Average Annual Recharge | 0.00 MG/yr |
| TN Mass Load | 11.30 kg/yr |
| TN Concentration | 0.00 mg/L |
| TP Mass Load | 1.62 kg/yr |
| TP Concentration | 0.00 mg/L |
Runoff input is only from this catchment, no routing is performed here
| N | 15.87 kg/yr |
| P | 2.28 kg/yr |
| Q | 5.36 ac-ft/yr |
| N | 71 % |
| P | 71 % |
| N | 4.57 kg/yr |
| P | 0.66 kg/yr |
| Q | 1.54 ac-ft/yr |
| N | 11.30 kg/yr |
| P | 1.62 kg/yr |
| Q | 3.82 ac-ft/yr |
The equations behind the values above, and the values they are worked with (v1's Equations page).
Storage (ac-ft) = Surface Area (ac) x Sum over layers [Layer Thickness (in) x Sustainable Void (%) / 100] x Layer Scale Factor / 12
Treatment Depth (in) = Storage / Watershed Area (ac) x 12
Sizing scales every pavement layer by the same factor: 1.0 is the layers as entered, 1.5 makes each layer half again as thick. Apply multiplies each layer thickness by the factor; Cancel leaves the layers as they were.
With no layers entered, sizing starts from 12 in of User Defined(20).
Hydraulic capture efficiency is read from the retention efficiency lookup tables for the Treatment Depth.
The lookup also depends on the watershed's non-DCIA curve number, DCIA percent and rainfall zone.
N and P removal are equal to the hydraulic capture efficiency.
A recovery-time adjustment for Time to Recover Design Volume is added to the capture efficiency and to N and P removal (see Recovery-Time Adjustment).
| Variable | Current value |
|---|---|
| Contributing Area | 1.500 ac |
| Watershed Area | 2.000 ac |
| Non-DCIA Curve Number | 80 |
| DCIA Percent | 70 % |
| Rainfall Zone | Florida Zone 3 |
| Treatment Depth | 1.005 in |
| Hydraulic Capture | 71.2 % |
| Treatment Rate | (no media mix) |
| N removal | 71.2 % |
| P removal | 71.2 % |