Permeable Pavement

Permeable pavement: commercial parking — Permeable Pavement on Commercial site (stand-alone: this catchment's runoff only)
Made by BMPFast 2 on Tuesday, 20 October 2026 16:00

Permeable Pavement Design Values

Pavement Surface Area0.50 acres
Total Storage of Pavement0.17 ac-ft
Watershed Area2.00 acres
Treatment Depth1.00 in
Time to Recover Design Volume72.00 hr

Treatment Depth (in) = Total Storage of Pavement (ac-ft) / Watershed Area (ac) x 12. The whole catchment area is used, pavement included. Permeable pavement is always calculated as a retention BMP.

Pavement Layers

Pavement TypeSustainable Void (%)Thickness (in)Storage (in over pavement)Storage (ac-ft)
Concrete Permeable Pavement25.006.001.5000.062
#57 rock(non-calcareous)21.0012.002.5200.105
Total4.0200.167

Watershed Characteristics

Watershed Area2.00 acres
Contributing Area to BMP1.50 ac
Watershed Non-DCIA Curve Number (0-100)80
Watershed DCIA Percent70.00 %
Rainfall ZoneFlorida Zone 3
Rainfall54.00 in

Surface Water Discharge

Provided Nitrogen Treatment Efficiency71.2 %
Provided Phosphorus Treatment Efficiency71.2 %

Groundwater Discharge (Stand-Alone)

Average Annual Recharge0.00 MG/yr
TN Mass Load11.30 kg/yr
TN Concentration0.00 mg/L
TP Mass Load1.62 kg/yr
TP Concentration0.00 mg/L

Surface Discharge Load Diagram for Permeable Pavement (stand-alone)

Runoff input is only from this catchment, no routing is performed here

Load

N15.87 kg/yr
P2.28 kg/yr
Q5.36 ac-ft/yr

Treatment

N71 %
P71 %

Surface Discharge

N4.57 kg/yr
P0.66 kg/yr
Q1.54 ac-ft/yr

Mass Reduction

N11.30 kg/yr
P1.62 kg/yr
Q3.82 ac-ft/yr

Equations

The equations behind the values above, and the values they are worked with (v1's Equations page).

Permeable Pavement — Equations

Equations

Storage (ac-ft) = Surface Area (ac) x Sum over layers [Layer Thickness (in) x Sustainable Void (%) / 100] x Layer Scale Factor / 12

Treatment Depth (in) = Storage / Watershed Area (ac) x 12

Notes

Sizing scales every pavement layer by the same factor: 1.0 is the layers as entered, 1.5 makes each layer half again as thick. Apply multiplies each layer thickness by the factor; Cancel leaves the layers as they were.

With no layers entered, sizing starts from 12 in of User Defined(20).

Hydraulic capture efficiency is read from the retention efficiency lookup tables for the Treatment Depth.

The lookup also depends on the watershed's non-DCIA curve number, DCIA percent and rainfall zone.

N and P removal are equal to the hydraulic capture efficiency.

A recovery-time adjustment for Time to Recover Design Volume is added to the capture efficiency and to N and P removal (see Recovery-Time Adjustment).

Values

VariableCurrent value
Contributing Area1.500 ac
Watershed Area2.000 ac
Non-DCIA Curve Number80
DCIA Percent70 %
Rainfall ZoneFlorida Zone 3
Treatment Depth1.005 in
Hydraulic Capture71.2 %
Treatment Rate(no media mix)
N removal71.2 %
P removal71.2 %