How this treatment's values are worked out: the equations, then the values they are worked with (v1's Equations button). A change on the Entry or Sizing tab shows here at once.
Storage (ac-ft) = Surface Area (ac) x Sum over layers [Layer Thickness (in) x Sustainable Void (%) / 100] x Layer Scale Factor / 12
Treatment Depth (in) = Storage / Watershed Area (ac) x 12
Sizing scales every pavement layer by the same factor: 1.0 is the layers as entered, 1.5 makes each layer half again as thick. Apply multiplies each layer thickness by the factor; Cancel leaves the layers as they were.
With no layers entered, sizing starts from 12 in of User Defined(20).
Hydraulic capture efficiency is read from the retention efficiency lookup tables for the Treatment Depth.
The lookup also depends on the watershed's non-DCIA curve number, DCIA percent and rainfall zone.
N and P removal are equal to the hydraulic capture efficiency.
A recovery-time adjustment for Time to Recover Design Volume is added to the capture efficiency and to N and P removal (see Recovery-Time Adjustment).
| Variable | Current value |
|---|---|
| Contributing Area | 1.800 ac |
| Watershed Area | 3.000 ac |
| Non-DCIA Curve Number | 80 |
| DCIA Percent | 70 % |
| Rainfall Zone | Florida Zone 4 |
| Treatment Depth | 2.392 in |
| Hydraulic Capture | 92.2 % |
| Treatment Rate | (no media mix) |
| N removal | 92.2 % |
| P removal | 92.2 % |