Routing 1

Rain garden: detention with underdrain — Catchment Routing results
Made by BMPFast 2 on Tuesday, 20 October 2026 16:00

Calculated with v1's engine, by Strand routing (v1's routing; use this for permits), so an opened v1 project gives the numbers v1 gives. This is the summary; v1's reports for this routing (Summary, Complete, Flow Balance, Full Routing Diagram, compliance, catchments and their treatments) are in the Report list above.

Nitrogen

Total Outlet Nitrogen Loading1.87 kg/yr
Total Catchment Nitrogen Loading4.68 kg/yr
Provided Nitrogen Treatment Efficiency60.00 %

Phosphorus

Total Outlet Phosphorus Loading0.13 kg/yr
Total Catchment Phosphorus Loading1.32 kg/yr
Provided Phosphorus Treatment Efficiency90.00 %

Runoff and area

Pre-development runoff volume0.18 ac-ft/yr
Post-development runoff volume leaving the site2.06 ac-ft/yr
Pre-Condition Catchment Area1.00 ac
Post Condition Catchment Area1.00 ac

Requirement

Type of analysisNet Improvement
Nitrogen removal for post = pre85.2 %
Phosphorus removal for post = pre89.7 %
Nitrogen removal to meet (the greater)85.2 %
Phosphorus removal to meet (the greater)89.7 %

Meets the required removal? Nitrogen: no (60.00 % provided, 85.2 % needed). Phosphorus: yes (90.00 % provided, 89.7 % needed). The removal needed is the greater of the type of analysis's percentage and the post = pre removal, as in v1's reports.

How each catchment is routed

CatchmentDrains toTreatment usedLeft out
TownhomesOutletRain Garden