Rain Garden — calculations

Rain garden: detention with underdrain — Rain Garden on Townhomes (stand-alone: this catchment's runoff only)
Made by BMPFast 2 on Tuesday, 20 October 2026 16:00

How this treatment's values are worked out: the equations, then the values they are worked with (v1's Equations button). A change on the Entry or Sizing tab shows here at once.

Equations

Storage Volume (cf) = Void Fraction x Media Volume + Water Above Media

Treatment Depth (in) = Storage Volume x 12 / (43560 x Contributing Area (ac))

Minimum Media Surface Area (sf) = 12 x Storage Volume (cf) / (2 days x 24 h/day x Media Rate (gpm/sf) x 96.25 (in/hr per gpm/sf))

Notes

Detention: no volume is retained, so hydraulic capture is 0.

In Appendix O's order: the media removal first, then the native soil and cover crop credit on what is left.

Removal = media reduction + (100 - media reduction) x Soil and Cover Crop Credit / 100.

Media reduction is the N or P reduction of the selected media mix; with no media mix it is 0.

Values

VariableCurrent value
Sustainable Void Fraction0.30 0-1
Water Above Media1,000.00 cubic feet
Credit for Native Soil and Cover Crop0.00 %
Media Volume2,000 cubic feet
Contributing Area1.000 ac
Watershed Area1.000 ac
Non-DCIA Curve Number80
DCIA Percent50 %
Rainfall ZoneFlorida Zone 4
Treatment Depth0.441 in
Media Rate0.052 gpm/sf
Minimum Media Surface Area80 sf
Hydraulic Capture0.0 %
Treatment Rate0.052 gpm/sf
N removal60.0 %
P removal90.0 %