| Retention or Detention | Retention |
| Type of Media Mix | B&G ECT Mixes |
| Sustainable Void Fraction (0-1) | 0.30 |
| Media Volume | 1,200 cubic feet |
| Water Above Media | 600.00 cubic feet |
| Provided retention volume for efficiency | 0.02 ac-ft |
| Provided Media Treatment Depth | 0.53 in |
| Credit for Native Soil and Cover Crop | 0.00 % |
| Minimum Media Surface Area to drain the storage in 48 hours | 2 sf |
| Watershed Area | 0.50 acres |
| Contributing Area to BMP | 0.50 ac |
| Watershed Non-DCIA Curve Number (0-100) | 80 |
| Watershed DCIA Percent | 80.00 % |
| Rainfall Zone | Florida Zone 2 |
| Rainfall | 50.00 in |
| Provided Nitrogen Treatment Efficiency | 52.3 % |
| Provided Phosphorus Treatment Efficiency | 52.3 % |
| Type of Media Mix | B&G ECT Mixes |
| Media N Reduction | 45.00 % |
| Media P Reduction | 45.00 % |
Note: Media Layer Depth not entered. B&G ECT Mixes needs at least 24 in (design guidance from the media suppliers; see the Media Mix help page). Enter the depth in Enter Media Mix Information to check it.
| Average Annual Recharge | 0.24 MG/yr |
| TN Mass Load | 0.46 kg/yr |
| TN Concentration | 0.51 mg/L |
| TP Mass Load | 0.09 kg/yr |
| TP Concentration | 0.10 mg/L |
Runoff input is only from this catchment, no routing is performed here
| N | 1.60 kg/yr |
| P | 0.33 kg/yr |
| Q | 1.40 ac-ft/yr |
| N | 52 % |
| P | 52 % |
| N | 0.76 kg/yr |
| P | 0.16 kg/yr |
| Q | 0.67 ac-ft/yr |
| N | 0.84 kg/yr |
| P | 0.17 kg/yr |
| Q | 0.73 ac-ft/yr |
The equations behind the values above, and the values they are worked with (v1's Equations page).
Storage Volume (cf) = Void Fraction x Media Volume + Water Above Media
Treatment Depth (in) = Storage Volume x 12 / (43560 x Contributing Area (ac))
Minimum Media Surface Area (sf) = 12 x Storage Volume (cf) / (2 days x 24 h/day x Media Rate (gpm/sf) x 96.25 (in/hr per gpm/sf))
Hydraulic capture efficiency is read from the retention efficiency lookup tables for the Treatment Depth.
The lookup also depends on the watershed's non-DCIA curve number, DCIA percent and rainfall zone.
N and P removal are equal to the hydraulic capture efficiency.
Removal = capture + Soil and Cover Crop Credit / 100 x (100 - capture).
| Variable | Current value |
|---|---|
| Sustainable Void Fraction | 0.30 0-1 |
| Water Above Media | 600.00 cubic feet |
| Credit for Native Soil and Cover Crop | 0.00 % |
| Media Volume | 1,200 cubic feet |
| Contributing Area | 0.500 ac |
| Watershed Area | 0.500 ac |
| Non-DCIA Curve Number | 80 |
| DCIA Percent | 80 % |
| Rainfall Zone | Florida Zone 2 |
| Treatment Depth | 0.529 in |
| Media Rate | 1.000 gpm/sf |
| Minimum Media Surface Area | 2 sf |
| Hydraulic Capture | 52.3 % |
| Treatment Rate | 1 gpm/sf |
| N removal | 52.3 % |
| P removal | 52.3 % |