Rainwater Harvesting

Rainwater harvesting: house with cistern — Rainwater Harvesting on Roof (stand-alone: this catchment's runoff only)
Made by BMPFast 2 on Tuesday, 20 October 2026 16:00

Rainwater Harvesting Input Variables

Contributing Area3,049.20 sf
Total Area Available for Irrigation5,000.00 sf
Available Harvest Volume1,500.00 gallons
Available Harvest Rate1.00 in/week
Equivalent Impervious Area2,923.27 sf
Harvest Volume0.82 in over EIA

Water Budget

Water Use162,078 gal/yr
Harvested Water Supply69,441 gal/yr
Supplemental Water Needed92,637 gal/yr

Supplemental Water Needed = Water Use - Harvested Water Supply (0 when the supply covers the use): the irrigation water that must come from another source.

Watershed Characteristics

Watershed Area0.07 acres
Contributing Area to BMP0.07 ac
Watershed Non-DCIA Curve Number (0-100)98
Watershed DCIA Percent100.00 %
Rainfall ZoneFlorida Zone 2
Rainfall50.00 in

Surface Water Discharge

Provided Nitrogen Treatment Efficiency76.2 %
Provided Phosphorus Treatment Efficiency76.2 %

Surface Discharge Load Diagram for Rainwater Harvesting (stand-alone)

Runoff input is only from this catchment, no routing is performed here

Load

N0.31 kg/yr
P0.03 kg/yr
Q0.24 ac-ft/yr

Treatment

N76 %
P76 %

Surface Discharge

N0.07 kg/yr
P0.01 kg/yr
Q0.06 ac-ft/yr

Mass Reduction

N0.23 kg/yr
P0.03 kg/yr
Q0.18 ac-ft/yr

Equations

The equations behind the values above, and the values they are worked with (v1's Equations page).

Rainwater Harvesting — Equations

Equations

Equivalent Impervious Area EIA (sf) = Contributing Area (sf) x Roof Factor

Volume over EIA (in) = Harvest Volume (gal) / 7.4805 gal/cf / EIA (sf) x 12

Harvest Rate (cf/day) = Harvest Rate (in/week) x Irrigation Area (sf) / (7 x 12)

Rate over EIA (in/day) = 12 x Harvest Rate (cf/day) / EIA (sf)

Harvest Efficiency (%) = REV table lookup of (Volume over EIA, Rate over EIA)

Water Use (gal/yr) = Harvest Rate (in/week) x 52 / 12 x Irrigation Area (sf) x 7.48052 gal/cf

Harvested Water Supply (gal/yr) = Harvest Efficiency / 100 x EIA (sf) x Annual Rainfall (in) / 12 x 7.48052 gal/cf

Supplemental Water Needed (gal/yr) = Water Use - Harvested Water Supply (0 when the supply covers the use)

Notes

Roof Factor is set by the selected Roof Type.

Harvest Efficiency is capped at 90%. Below 20%, the lowest REV curve, it is extended along the line between the 20% and 30% curves (beyond the published curves).

N and P removal are equal to the Harvest Efficiency.

The Harvested Water Supply is the share of the runoff from the EIA that the harvest captures.

Values: the harvest efficiency is read from the REV curves of the Rainfall Zone. Non-DCIA Curve Number, DCIA Percent and Treatment Rate are listed for every retention-type BMP but are not used to calculate the harvest efficiency. Treatment Depth is always 0 for Rainwater Harvesting.

Values

VariableCurrent value
Total Area Available for Irrigation5,000.00 sf
Available Harvest Volume1,500.00 gallons
Available Harvest Rate1.00 in/week
Contributing Area3,049 sf
Watershed Area3,049 sf
Non-DCIA Curve Number98
DCIA Percent100 %
Rainfall ZoneFlorida Zone 2
Treatment Depth0.000 in
Hydraulic Capture76.0 %
Treatment Rate(no media mix)
N removal76.2 %
P removal76.2 %