| Contributing Area | 43,560.00 sf |
| Total Area Available for Irrigation | 87,120.00 sf |
| Available Harvest Volume | 30,000.00 gallons |
| Available Harvest Rate | 1.50 in/week |
| Equivalent Impervious Area | 41,517.04 sf |
| Harvest Volume | 1.16 in over EIA |
| Water Use | 4,236,069 gal/yr |
| Harvested Water Supply | 1,182,558 gal/yr |
| Supplemental Water Needed | 3,053,510 gal/yr |
Supplemental Water Needed = Water Use - Harvested Water Supply (0 when the supply covers the use): the irrigation water that must come from another source.
| Watershed Area | 1.00 acres |
| Contributing Area to BMP | 1.00 ac |
| Watershed Non-DCIA Curve Number (0-100) | 98 |
| Watershed DCIA Percent | 100.00 % |
| Rainfall Zone | Florida Zone 3 |
| Rainfall | 54.00 in |
| Provided Nitrogen Treatment Efficiency | 84.6 % |
| Provided Phosphorus Treatment Efficiency | 84.6 % |
Runoff input is only from this catchment, no routing is performed here
| N | 4.63 kg/yr |
| P | 0.53 kg/yr |
| Q | 3.58 ac-ft/yr |
| N | 85 % |
| P | 85 % |
| N | 0.71 kg/yr |
| P | 0.08 kg/yr |
| Q | 0.54 ac-ft/yr |
| N | 3.92 kg/yr |
| P | 0.45 kg/yr |
| Q | 3.04 ac-ft/yr |
The equations behind the values above, and the values they are worked with (v1's Equations page).
Equivalent Impervious Area EIA (sf) = Contributing Area (sf) x Roof Factor
Volume over EIA (in) = Harvest Volume (gal) / 7.4805 gal/cf / EIA (sf) x 12
Harvest Rate (cf/day) = Harvest Rate (in/week) x Irrigation Area (sf) / (7 x 12)
Rate over EIA (in/day) = 12 x Harvest Rate (cf/day) / EIA (sf)
Harvest Efficiency (%) = REV table lookup of (Volume over EIA, Rate over EIA)
Water Use (gal/yr) = Harvest Rate (in/week) x 52 / 12 x Irrigation Area (sf) x 7.48052 gal/cf
Harvested Water Supply (gal/yr) = Harvest Efficiency / 100 x EIA (sf) x Annual Rainfall (in) / 12 x 7.48052 gal/cf
Supplemental Water Needed (gal/yr) = Water Use - Harvested Water Supply (0 when the supply covers the use)
Roof Factor is set by the selected Roof Type.
Harvest Efficiency is capped at 90%. Below 20%, the lowest REV curve, it is extended along the line between the 20% and 30% curves (beyond the published curves).
N and P removal are equal to the Harvest Efficiency.
The Harvested Water Supply is the share of the runoff from the EIA that the harvest captures.
Values: the harvest efficiency is read from the REV curves of the Rainfall Zone. Non-DCIA Curve Number, DCIA Percent and Treatment Rate are listed for every retention-type BMP but are not used to calculate the harvest efficiency. Treatment Depth is always 0 for Rainwater Harvesting.
| Variable | Current value |
|---|---|
| Total Area Available for Irrigation | 87,120.00 sf |
| Available Harvest Volume | 30,000.00 gallons |
| Available Harvest Rate | 1.50 in/week |
| Contributing Area | 43,560 sf |
| Watershed Area | 43,560 sf |
| Non-DCIA Curve Number | 98 |
| DCIA Percent | 100 % |
| Rainfall Zone | Florida Zone 3 |
| Treatment Depth | 0.000 in |
| Hydraulic Capture | 85.0 % |
| Treatment Rate | (no media mix) |
| N removal | 84.6 % |
| P removal | 84.6 % |