Rainwater Harvesting — calculations

Rainwater harvesting: school, flat roof — Rainwater Harvesting on School roof (stand-alone: this catchment's runoff only)
Made by BMPFast 2 on Tuesday, 20 October 2026 16:00

How this treatment's values are worked out: the equations, then the values they are worked with (v1's Equations button). A change on the Entry or Sizing tab shows here at once.

Equations

Equivalent Impervious Area EIA (sf) = Contributing Area (sf) x Roof Factor

Volume over EIA (in) = Harvest Volume (gal) / 7.4805 gal/cf / EIA (sf) x 12

Harvest Rate (cf/day) = Harvest Rate (in/week) x Irrigation Area (sf) / (7 x 12)

Rate over EIA (in/day) = 12 x Harvest Rate (cf/day) / EIA (sf)

Harvest Efficiency (%) = REV table lookup of (Volume over EIA, Rate over EIA)

Water Use (gal/yr) = Harvest Rate (in/week) x 52 / 12 x Irrigation Area (sf) x 7.48052 gal/cf

Harvested Water Supply (gal/yr) = Harvest Efficiency / 100 x EIA (sf) x Annual Rainfall (in) / 12 x 7.48052 gal/cf

Supplemental Water Needed (gal/yr) = Water Use - Harvested Water Supply (0 when the supply covers the use)

Notes

Roof Factor is set by the selected Roof Type.

Harvest Efficiency is capped at 90%. Below 20%, the lowest REV curve, it is extended along the line between the 20% and 30% curves (beyond the published curves).

N and P removal are equal to the Harvest Efficiency.

The Harvested Water Supply is the share of the runoff from the EIA that the harvest captures.

Values: the harvest efficiency is read from the REV curves of the Rainfall Zone. Non-DCIA Curve Number, DCIA Percent and Treatment Rate are listed for every retention-type BMP but are not used to calculate the harvest efficiency. Treatment Depth is always 0 for Rainwater Harvesting.

Values

VariableCurrent value
Total Area Available for Irrigation87,120.00 sf
Available Harvest Volume30,000.00 gallons
Available Harvest Rate1.50 in/week
Contributing Area43,560 sf
Watershed Area43,560 sf
Non-DCIA Curve Number98
DCIA Percent100 %
Rainfall ZoneFlorida Zone 3
Treatment Depth0.000 in
Hydraulic Capture85.0 %
Treatment Rate(no media mix)
N removal84.6 %
P removal84.6 %