Retention
Example Problem # 3 — Retention on catchment 1 (stand-alone: this catchment's runoff only)
Made by BMPFast 2 on Tuesday, 20 October 2026 16:00
Retention Input Variables
| Treatment Depth | 0.55 in |
| Retention Volume | 0.506 ac-ft |
| Time to Recover Design Volume | 72.00 hr |
Watershed Characteristics
| Watershed Area | 11.00 acres |
| Contributing Area to BMP | 11.00 ac |
| Watershed Non-DCIA Curve Number (0-100) | 65 |
| Watershed DCIA Percent | 25.00 % |
| Rainfall Zone | Florida Zone 4 |
| Rainfall | 50.00 in |
Surface Water Discharge
| Provided Nitrogen Treatment Efficiency | 75.0 % |
| Provided Phosphorus Treatment Efficiency | 75.0 % |
Surface Discharge Load Diagram for Retention (stand-alone)
Runoff input is only from this catchment, no routing is performed here
Load
| N | 24.61 kg/yr |
| P | 4.55 kg/yr |
| Q | 11.28 ac-ft/yr |
Treatment
Surface Discharge
| N | 6.15 kg/yr |
| P | 1.14 kg/yr |
| Q | 2.82 ac-ft/yr |
Mass Reduction
| N | 18.46 kg/yr |
| P | 3.41 kg/yr |
| Q | 8.46 ac-ft/yr |
Equations
The equations behind the values above, and the values they are worked with (v1's Equations page).
Retention — Equations
Equations
Treatment Depth (in) = Retention Volume (ac-ft) / Contributing Area (ac) x 12
Notes
Hydraulic capture efficiency is read from the retention efficiency lookup tables for the Treatment Depth.
The lookup also depends on the watershed's non-DCIA curve number, DCIA percent and rainfall zone.
N and P removal are equal to the hydraulic capture efficiency.
Values
| Variable | Current value |
| Retention Volume | 0.506 ac-ft |
| Contributing Area | 11.000 ac |
| Watershed Area | 11.000 ac |
| Non-DCIA Curve Number | 65 |
| DCIA Percent | 25 % |
| Rainfall Zone | Florida Zone 4 |
| Treatment Depth | 0.552 in |
| Hydraulic Capture | 75.0 % |
| Treatment Rate | (no media mix) |
| N removal | 75.0 % |
| P removal | 75.0 % |